PALATINE, IL ·
OSHA Inspection: MAGYAN CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAGYAN CORPORATION in 144 E PALATINE ROAD, PALATINE, IL 60067 (NAICS 238160). OSHA activity number 339416208.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGYAN CORPORATION
- Site address
- 144 E PALATINE ROAD
- City
- PALATINE
- State
- IL
- ZIP
- 60067
- Mailing
- 7610 GLADSTONE DRIVE #106, NAPERVILLE, IL 60565
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.452 M01
- Issued
- Sep 18, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance: a) Ladders used as crawling boards ("chicken" ladders) did not extend from the roof peak to the eave when used during roofing work. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.452 M02
- Issued
- Sep 18, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability): a) Ladders used as crawling boards ("chicken ladders) were not secured to the roof by ridge hooks or by other means. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B10
- Issued
- Sep 18, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) Employees were exposed to the hazard of falling approximately 18 feet from the edge of the roof deck while engaged in roofing activities without the use of fall protection or a safety monitor. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1926.501 B11
- Issued
- Sep 18, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toe boards, safety net systems, or personal fall arrest systems: a) Employees were not protected from the hazard of falling while working from a steep pitched roof (approximately 10/12 pitch) with a ground to eave height of about 18 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1926.552 A01
- Issued
- Sep 18, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators: a) Employees were using a material hoist as a ladder to access the roof. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
More inspections at Magyan Corporation