OKLAHOMA CITY, OK —
OSHA Inspection: AERO COMPONENTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AERO COMPONENTS, INC. in 535 S.E. 82ND ST., OKLAHOMA CITY, OK 73149 (NAICS 332710). OSHA activity number 339441628.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AERO COMPONENTS, INC.
- Site address
- 535 S.E. 82ND ST.
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73149
- Mailing
- 535 S.E. 82ND ST., OKLAHOMA CITY, OK 73149
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Nov 26, 2013
- Abate by
- Jan 13, 2014
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about October 25, 2013, and at times prior thereto, at the establishment the employer did not establish a Lockout/Tag-out program consisting of an energy control procedures, employee training and periodic inspections in maintenance operations. Employees were exposed to unexpected release of energy hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.303 B02
- Issued
- Nov 26, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about July 24, 2013, and at times prior thereto, at a grinding machine area a four-plex electrical outlet box was observed being used not in accordance with the listed instructions where it was not mounted on wall or structure. Employees were exposed to electric shock hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.304 B02
- Issued
- Nov 26, 2013
- Abate by
- Dec 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about October 25, 2013, or at times prior thereto, in building #5 areas two microwave ovens were plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Aero Components, INC.
View Aero Components, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339441628.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.