CORSICANA, TX ·
OSHA Inspection: SONIC COMPONENT SYSTEMS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SONIC COMPONENT SYSTEMS LLC in 1101 N BUSINESS 45, CORSICANA, TX 75110 (NAICS 332618). OSHA activity number 339444663.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SONIC COMPONENT SYSTEMS LLC
- Site address
- 1101 N BUSINESS 45
- City
- CORSICANA
- State
- TX
- ZIP
- 75110
- Mailing
- 1101 N BUSINESS 45, CORSICANA, TX 75110
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 51
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Jan 3, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $4,620 · Current $3,003 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. On or about October 31, 2013 and at times prior thereto, employees operated Lian Rou LR-PS-90P pocket spring coilers in the pocket coil department and were exposed to tripping and falling hazards: a) On the floor at number 1 pocket spring coiler, the 240 volt flexible power cable; b) On the floor at number 2 pocket spring coiler, the 240 volt flexible power cable; c) On the floor at number 3 pocket spring coiler, the 240 volt flexible power cable; d) On the floor at number 4 pocket spring coiler, the 240 volt flexible power cable; e) On the floor at number 5 pocket spring coiler, the 240 volt flexible power cable; f) On the floor at number 6 pocket spring coiler, the 240 volt flexible power cable; g) On the floor at number 7 pocket spring coiler, the 240 volt flexible power cable; h) On the floor at number 8 pocket spring coiler, the 240 volt flexible power cable; i) On the floor at number 9 pocket spring coiler, the 240 volt flexible power cable; and j) On the floor at number 10 pocket spring coiler, the 240 volt flexible power cable.
Recent events (2)
- · I (S) $3003
- · Z (S) $4620
1910.22 A02
- Issued
- Jan 3, 2014
- Abate by
- Feb 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition. On or about October 31, 2013 and at times prior thereto, employees working in the bonnell department were exposed to slip and fall hazards where water leaking from the roof accumulated on the floor: a) At the sliding bay door entering into the bonnell department where the border rod machines were operated; b) At the queen and king border rod 6 gauge wire machine and equipment; and c) At the twin and full border rod 6 gauge wire machine and equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.36 B01
- Issued
- Jan 3, 2014
- Abate by
- Feb 25, 2014
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
29 CFR 1910.36(b)(1): Two exit routes. At least two exit routes was not available in the workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route. On or about October 31, 2013 and at times prior thereto, the employer did not ensure that exit doors were available or at least two exit routes were available in the workplace for emergency evacuation. Employees were exposed to the hazard of entrapment and fire: a) In the bonnell department where the border rod machines were operated, and b) In the pocket coiler department.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.37 A03
- Issued
- Jan 3, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp were not provided where the exit route was not substantially level: On or about October 31, 2013 and at times prior thereto, in the pocket coiler department, the employer did not ensure that the exit routes were free and unobstructed by items such as but not limited to storage racks/carts, boxes, pallets, stacked materials and wire coil bundles, and equipment. Employees were exposed to the hazards of entrapment and fire.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.37 B04
- Issued
- Jan 3, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent. On or about October 31, 2013, and at times prior thereto, the employer did not ensure that "exit routes" leading to an exit were immediately apparent. The employer did not have arrows, signs or directional aids to aid in the evacuation process, exposing employees to entrapment hazards: a) In the bonnell department, where the border rod machines were operated, and b) In the pocket coiler department
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.132 D01 I
- Issued
- Jan 3, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $2,310 · Current $1,502 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: On or about October 31, 2013 and at times prior thereto, the employer did not select or provide adequate personal protective equipment such as but not limited to arm length gloves, aprons, or face shields, when employees loaded hot glue into the two Sure Tack STS hot glue tanks. Employees were exposed to the hazard of being burned by the 400 degree chemical glue.
Recent events (2)
- · I (S) $1501.5
- · Z (S) $2310
1910.212 A01
- Issued
- Jan 3, 2014
- Abate by
- Apr 8, 2014
- Penalty
- Initial $10,780 · Current $7,007 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about October 31, 2013 and at times prior thereto, in the pocket coiler department, the employer did not ensure machine guarding or methods to protect employees from amputation and caught-in hazards where utilized: a) on the Lian Rou LR-PS-90P pocket spring coilers number one through ten, the installed protective doors were not being closed when the machines were in operation, and b) on the Lian Rou LR-PS-90P pocket spring coilers number one through ten, the installed protective doors did not have interlock systems to prevent the machines from operating when the doors were opened. The Sonic Component Systems LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 891977, citation number one, item number 1a and was affirmed as a final order on 06/21/2013, with respect to a workplace located at 1101 N Business 45 Corsicana, Texas.
Recent events (2)
- · I (R) $7007
- · Z (R) $10780
1910.219 F03
- Issued
- Jan 3, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $7,700 · Current $5,005 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: On or about October 31, 2013, and at times prior thereto, in the bonnell department employees operated two border rod machines and the rotating 4 inch sprockets and chains were not guarded exposing employees to being caught-in and amputation hazards; a) The queen and king border rod machine had the side guard opened and the bottom of the machine did not have a guard, and b) The twin and full border rod machine did not have a bottom guard. The Sonic Component Systems LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.219(f)(3), which was contained in OSHA inspection number 891977, citation number 1, item number 2 and was affirmed as a final order on 06/21/2013, with respect to a workplace located at 1101 N Business 45 Corsicana, Texas.
Recent events (2)
- · I (R) $5005
- · Z (R) $7700
1910.305 G02 III
- Issued
- Jan 3, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $7,700 · Current $5,005 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. On or about October 31, 2013 and at times prior thereto, the employer did not ensure that strain relief devices were installed to prevent strain or pull of the electrical conductors and cords, exposing employees to the hazards of electrical shock and fire: a) In the pocket coiler department, employees operated ten (10) Lian Rou LR-PS-90P pocket spring machines and wire coil turntables with 240 volt flexible cords with strain and conductors visible, and b) In the bonnell department, the cable sheathing of a two wire 120 volt electrical outlet system was pulled away from the outlet handy box. The Sonic Component Systems LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(2)(iii), which was contained in OSHA inspection number 891977, citation number 1, item number 4b and was affirmed as a final order on 06/21/2013, with respect to a workplace located at 1101 N Business 45 Corsicana, Texas.
Recent events (2)
- · I (R) $5005
- · Z (R) $7700
More inspections at Sonic Component Systems LLC
View Sonic Component Systems LLC's full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339444663.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.