HORSEHEADS, NY —
OSHA Inspection: BENNETT TOOL & DIE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BENNETT TOOL & DIE INC. in 130 WYGANT ROAD, HORSEHEADS, NY 14845 (NAICS 333514). OSHA activity number 339445413.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BENNETT TOOL & DIE INC.
- Site address
- 130 WYGANT ROAD
- City
- HORSEHEADS
- State
- NY
- ZIP
- 14845
- Mailing
- 130 WYGANT ROAD, HORSEHEADS, NY 14845
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333514
- Employees
- 34
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.215 A04
- Issued
- Jan 17, 2014
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work(s) to support offhand grinding work: a) West Building, on or about 10/24/13: A DoAll Bench Grinder was used without a work rest on left side of wheel to support offhand grinding.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.215 B09
- Issued
- Jan 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) West Building, on or about 10/24/13: DoAll Grinder was missing tongue guard on left side of wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Jan 17, 2014
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) West Building, on or about 10/24/13: A 120/240 volt breaker panel box had one blank missing one.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.212 A01
- Issued
- Jan 17, 2014
- Penalty
- Initial $5,600 · Current $3,920 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) General Tool Room No. 1, on or about 10/24/13: 301 and 304 Bridgeport Milling Machines and 302; 319; 320 and no number Chevalier Milling Machines were not provided with chuck and tool guards. b) General Tool Room No. 2, on or about 10/24/13: 208; 213 and 303 Bridgeport Milling Machines and 231 and 306 Chevalier Milling Machines were not provided with chuck and tool guards. c) General Tool Room No. 2, on or about 10/24/13: DoAll Drill Press was not provided with a chuck and tool guard. d) West Building, on or about 10/24/13: Bridgeport 212 Milling Machine was not provided with a chuck and tool guard. e) West Building, on or about 10/24/13: South Bend Precision Lathe the rotating chuck was not guarded. Bennett Die & Tool, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(1), which was contained in OSHA inspection number 312370968, citation number 1, item number 3 and was affirmed as a final order on 9/21/09, with respect to a workplace located at 130 612 Elmira Road, Ithaca, NY 14850.
Recent events (2)
- — I (R) $3920
- — Z (R) $5600
1910.303 B02
- Issued
- Jan 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Automatic Area, on or about 10/24/13: A flexible cord with a duplex metal receptacle box attached used to provide power to a drill. The metal box is listed for permanent mounting only.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Bennett Tool & DIE INC.
View Bennett Tool & DIE INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333514)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339445413.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.