Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IEC HOLDEN CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of IEC HOLDEN CORPORATION in 51 DISTRIBUTION WAY SUITE102, PLATTSBURGH, NY 12901 (NAICS 335312). OSHA activity number 339455768.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IEC Holden Corporation — free Get an email when a new federal OSHA severe-injury report for IEC Holden Corporation is published. One employer, no account, unsubscribe in one click.
Site address
51 DISTRIBUTION WAY SUITE102
City
PLATTSBURGH
State
NY
ZIP
12901
Mailing
51 DISTRIBUTION WAY SUITE102, PLATTSBURGH, NY 12901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335312
Employees
34
Ownership type
A

5 citations on file for this inspection.

1910.132 D01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Jan 17, 2014
Penalty
Initial $4,500 · Current $2,500 Reduced

Hazardous substances 24602582

29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:    (a) On or about 10/31/2013 at IEC Holden Corporation, for the employees operating the VPI unit. The eye protection provided by the employer did not protect employees' eyes from liquid vinyl toluene when they are handling/removing the parts from tank.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4500

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Jan 31, 2014
Penalty
Initial $2,700 · Current $1,500 Reduced

Hazardous substances 24602582

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) On or about 10/31/2013 at IEC Holden Corporation, for employees operating the VPI unit who were required to wear tight-fitting half-face 3M respirators with organic vapor cartridges .  The employer did not establish a site-specific respiratory protection program that met the requirements of the standard.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2700

1910.146 C02

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Jan 17, 2014
Penalty
Initial $2,700 · Current $1,500 Reduced

Hazardous substances 24602582

29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:     (a) On or about 10/31/2013 at IEC Holden Corporation, for the employees operating the VPI unit who were required to open, remove parts from, and would clean inside the VPI unit.  The employer did not post a sign on the VPI unit with an appropriate label designating it as a permit-required confined space.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2700

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Jan 31, 2014
Penalty
Initial $3,600 · Current $2,000 Reduced

Hazardous substances 2582

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) On or about 10/31/2013 at IEC Holden Corporation, for the employees operating the VPI unit who were exposed to chemicals including but not limited to vinyl toluene, which targets the eyes and central nervous system as an irritant, and can be explosive when mixed with air. The employer did not develop and implement an effective hazard communication program.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3600

1910.1200 H03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2013
Abate by
Jan 17, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 2582

29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:  (a) On or about 10/31/2013 at IEC Holden Corporation, for the employees operating the VPI unit who were exposed to chemicals including but not limited to vinyl toluene, which targets the eyes and central nervous system as an irritant, and can be explosive when mixed with air. The employer did not implement an effective hazard communication training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View IEC Holden Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339455768.