Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VFORGE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of VFORGE, INC. in 5567 W. 6TH AVENUE, LAKEWOOD, CO 80214 (NAICS 332116). OSHA activity number 339464752.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vforge, INC. — free Get an email when a new federal OSHA severe-injury report for Vforge, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VFORGE, INC.
Site address
5567 W. 6TH AVENUE
City
LAKEWOOD
State
CO
ZIP
80214
Mailing
5567 W. 6TH AVENUE, LAKEWOOD, CO 80214
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
67
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 III

Serious Gravity 5 3 instances 3 exposed
Issued
Jan 27, 2014
Abate by
May 21, 2014
Penalty
Initial $3,570 · Current $1,785 Reduced
29 CFR 1910.212(a)(3)(iii): Special hand tools for placing and removing material(s) were not provided to permit easy handling of material without the operator placing a hand in the danger zone:  1) On October 29, 2013, and at prior times, bandsaw operators were exposed to the hazard of having their hand contact the point of operation portion of the saw when cutting metal pieces.  The employer had not provided hand tools to prevent employees from coming into contact with the point of operation.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1785
  • — Z (S) $3570

1910.305 G01 III

Serious Gravity 5 2 instances 1 exposed
Issued
Jan 27, 2014
Abate by
Feb 21, 2014
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited    by subparagraphs (A) through (E) of this paragraph:      1) On October 29, 2013, and at prior times, a flexible electrical cord was used for purposes prohibited by this standard in the following instances:      a) Where, in the place of permanent wiring in conduit, the cable ran from a breaker panel to an electrical outlet in the heat treat area      b) Where the cable ran through a hole in a wall.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

View Vforge, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339464752.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.