CREAM RIDGE, NJ —
OSHA Inspection: MILLER MASONRY, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MILLER MASONRY, LLC. in 1 WEATHERVANE CIRCLE, CREAM RIDGE, NJ 08514 (NAICS 238140). OSHA activity number 339469314.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILLER MASONRY, LLC.
- Site address
- 1 WEATHERVANE CIRCLE
- City
- CREAM RIDGE
- State
- NJ
- ZIP
- 08514
- Mailing
- 1609 MAKEFIELD ROAD, YARDLEY, PA 19067
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when performing red brick installation from a prefabricated, tubular welded framed scaffold whose walking/working surface was not fully planked and only contained 2-3 planks rather than the required 5-6. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1926.451 B10
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user: (a) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when performing red brick installation from a prefabricated, tubular welded framed scaffold system that contained intermixed components. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 E01
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) 1 Weathervane Circle, Upper Freehold Township NJ: Employees were accessing and egressing the walking/working surfaces of the scaffold (in excess of 13 feet to the ground surface below) by climbing the end frames. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 F03
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when performing red brick installation from a prefabricated, tubular welded framed scaffold system that contained intermixed and damaged components, was not fully planked on the level of the scaffold's activity, did not contain mid/top rails and endstops, did not have direct access to the scaffold's walking/working surface, etc. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 F04
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. (a) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when performing red brick installation from a prefabricated, tubular welded framed scaffold system that contained damaged/bent crossbraces and endframe. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 G01
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when performing red brick installation from a prefabricated, tubular welded framed scaffolds side bracket located on the third buck. The side bracket was missing endstops. Observed on or about 11/06/13. (b) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when accessing and egressing the scaffold's walking/working surface from areas that were missing mid and top rails. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.452 C02
- Issued
- Dec 13, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(DESCRIBE HAZARD(S) WHERE NECESSARY) (a) 1 Weathervane Circle, Upper Freehold Township NJ: An employee was exposed to falls, in excess of 13 feet to the ground surface below, when performing red brick installation from a prefabricated, tubular welded framed scaffold system that was missing cross bracing. Observed on or about 11/06/13. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at Miller Masonry, LLC.
View Miller Masonry, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339469314.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.