Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: STEEL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STEEL, LLC in 405 N. CLARENDON AVENUE, SCOTTDALE, GA 30079 (NAICS 332312). OSHA activity number 339477739.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steel, LLC for free Get an email when a new federal OSHA severe-injury report for Steel, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
STEEL, LLC
Site address
405 N. CLARENDON AVENUE
City
SCOTTDALE
State
GA
ZIP
30079
Mailing
405 N. CLARENDON AVENUE, SCOTTDALE, GA 30079
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
135
Ownership type
Private (A)

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 22, 2014
Abate by
Jan 28, 2014
Penalty
Initial $3,443 · Current $2,066 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazard from the damaged overhead crane hooks.    The hauling hooks on the overhead cranes were missing and/or had damaged safety latches designed to prevents equipment/steel beam from coming off the hook while in the midst of hauling the steel beam to areas of the shop, on  or about 11/06/13.         a.  Three-Ton Overhead Crane (#87269) - Safety latch was missing from the hook        b.  Three-Ton Overhead Crane (#87266) - Safety latch spring pin is broken making the safety latch ineffective, loose and not properly secured.  There was a large gap/space where material can slide off  the hook.      c.  Ten-Ton Overhead Crane (#87276) - Safety latch spring pin is broken making the safety latch ineffective, loose and not properly secured.  There was a large gap/space where material can slide off the hook.    Among other methods, one feasible and acceptable method to correct this hazard is to follow the Hooks ASME B30.10-1993, Section 10-1.2.3 Maintenance.
Recent events (2)
  • · I (S) $2066
  • · Z (S) $3443

1910.147 C04 II C

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 22, 2014
Abate by
Feb 18, 2014
Penalty
Initial $3,443 · Current $2,066 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:     a.  405 N. Clarendon Avenue, Scottdale, GA (Shop Area) - Employees were exposed to sudden energization or start-up of multi-energy source.  The company's lockout/tagout machine specific procedures did not include specific steps for the removal of locks and restoring the lockout/tagout equipment back into services.  Equipment includes but is not limited to, the Challenge Burn Table, Peddingghaus Anglemaster and Overhead Cranes, on or about 11/06/13.
Recent events (2)
  • · I (S) $2066
  • · Z (S) $3443

1910.147 C04 II D

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 22, 2014
Abate by
Feb 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control:     a.  405 N. Clarendon Avenue, Scottdale, GA (Shop Area) - Employees were exposed to sudden energization or start-up of multi-energy source.  The company's lockout/tagout machine specific procedures did not include specific steps for testing the machines or equipment to determine and verify the effectiveness of lockout devices, tagout devices and other energy control measures.  Equipment includes but is not limited to, the Challenge Burn Table, Peddinghaus Anglemaster and Overhead Cranes, on or  about 11/06/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.179 J02

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 22, 2014
Abate by
Feb 18, 2014
Penalty
Initial $2,066 · Current $1,240 Reduced
29 CFR 1910.179(j)(2): Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment, deterioration or leakage of air or hydraulic systems and hooks:     a.  405 N. Clarendon Avenue, Scottdale, GA (Overhead Cranes/Shop Area) - Employees were exposed to struck-by/overhead hazard.  Daily inspection were not effective.  There were deficiencies found such as, but not limited to the crane's hook being damaged and/or missing, on or about 11/06/13.
Recent events (2)
  • · I (S) $1240
  • · Z (S) $2066

1910.179 J02 IV

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 22, 2014
Abate by
Feb 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed:   a.  405 N. Clarendon Avenue, Scottdale, GA (Overhead Cranes/Shop Area) - Employees were exposed to struck-by/overhead hazard.  The employer has not maintained and/or provided the monthly inspections records of the drum hoist chains, on or about 11/06/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.252 B02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 22, 2014
Abate by
Jan 28, 2014
Penalty
Initial $2,754 · Current $1,651 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:     a.     405 N. Clarendon Avenue, Scottdale, GA - The adjacent employees were exposed to welding rays hazard.   The employer did not utilize protective welding screens and/or shields in areas adjacent to where the hand welding work was being performed, In addition, there were damaged welding screens being used, on or about 11/06/13.             a.  Small Bay Area       b.  Middle Bay Area
Recent events (2)
  • · I (S) $1651
  • · Z (S) $2754

1910.303 B07 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 22, 2014
Abate by
Feb 18, 2014
Penalty
Initial $2,066 · Current $1,240 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating:            a.   405 N. Clarendon Avenue, Scottdale, GA (Maintenance Shop) - Employees were exposed to electrical shock hazard. The 240V electrical disconnect box which controls the lights and equipment was damaged/bent preventing the front cover door from completely closing, exposing live wires, on or about 11/06/13.
Recent events (2)
  • · I (S) $1240
  • · Z (S) $2066

1904.29 B01

Repeat 1 instance 1 exposed
Issued
Jan 22, 2014
Abate by
Feb 18, 2014
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail as required by the regulation.   a.  OSHA 300 form for 2013 - Column F did not include a description of the injury or illness, and object/substance that directly injured or made the person ill.  (For case #9), on or about 11/06/13.  Steel, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1904.29(b)(1), which was contained in OSHA inspection number 312524713, citation number 2, item number 1 and was affirmed as a final order on March 13, 2009, with respect to a workplace located at 405 N. Clarendon Avenue, Scottdale, Georgia.
Recent events (2)
  • · I (R) $1080
  • · Z (R) $1800

View Steel, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339477739.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.