Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: GLACIER TOOL & DIE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GLACIER TOOL & DIE INC. in 3961 US HWY 93 N., STEVENSVILLE, MT 59870 (NAICS 332994). OSHA activity number 339478943.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Glacier Tool & DIE INC. for free Get an email when a new federal OSHA severe-injury report for Glacier Tool & DIE INC. is published. One employer, no account, unsubscribe in one click.
Site address
3961 US HWY 93 N.
City
STEVENSVILLE
State
MT
ZIP
59870
Mailing
3961 US HWY 93 N., STEVENSVILLE, MT 59870
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332994
Employees
15
Ownership type
Private (A)

9 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 25, 2014
Abate by
May 10, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      a) Glacier Tool & Die: On or about November 07, 2013, and at times prior, employees were exposed to unexpected release of energy while performing maintenance, clearing jams, and adjusting equipment such as, but not limited to the BenchMaster 5-ton press, without the protection of a machine specific procedural steps.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 25, 2014
Abate by
Apr 18, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a) Shop: On or about November 07, 2013, and at times prior, employees were exposed to caught-by and/or struck-by injuries while operating the unguarded Wilton Variable Speed drill press.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.212 B

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 25, 2014
Abate by
Apr 18, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a) Shop: On or about November 07, 2013, and at times prior, employees were exposed to potential struck-by hazards while operating the Wilton Variable Speed drill press.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.217 C01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 25, 2014
Abate by
Apr 18, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):  a) Shop: On or about October 29, 2013, and at times prior, employees were exposed to amputations while operating the unguarded BenchMaster 5-ton punch press.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $7000

1910.217 F02

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 25, 2014
Abate by
Apr 18, 2014
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.217(f)(2): Operator(s) were not trained and instructed in the safe method of work before starting work on mechanical power press(es):       a) Shop: On or about October 29, 2013, and at times prior, employees were exposed amputations hazards while operating equipment such as,  but not limited to, the unguarded BenchMaster 5-ton punch press without adequate training in the recognition of the hazards or the correct means to control these hazards, during punch press operations.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $7000

1910.219 D01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 25, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):     (a) Shop: On or about October 29, 2013, and at times prior, employees were exposed to amputations and caught-by hazards while operating a BenchMaster 5-ton punch press with an unguarded pulley on the drive motor.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.219 E01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   (a) Shop: On or about October 29, 2013, and at times prior, employees were exposed to amputation hazards while operating a BenchMaster 5-ton punch press with an unguarded belt on the drive motor.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 25, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s):      a) Shop: On or about October 29, 2013, and at times prior, employees were exposed to caught-by hazards while operating the BenchMaster 5 ton punch press with an unguarded keyed shaft end.
Recent events (2)
  • · I (S) $600
  • · Z (S) $1200

1910.303 G01 II

Serious Gravity 5 2 instances 6 exposed
Issued
Mar 25, 2014
Abate by
Apr 18, 2014
Penalty
Initial $1,600 · Current $500 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) Storage Room:  On or about November 07, 2013, and at times prior, employees were exposed to the hazards associated with not being able to de-energize equipment in the event of an emergency from a blocked, 220 volt electric panel.    b) Panel Finishing Area: On or about November 07, 2013, and at times prior, employees were exposed to the hazards  associated with not being able to de-energize equipment in the event of an emergency from a blocked, 120 volt electric panel.
Recent events (2)
  • · I (S) $500
  • · Z (S) $1600

View Glacier Tool & DIE INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339478943.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.