Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEMTROL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TEMTROL, INC. in 15 E OKLAHOMA AVE, OKARCHE, OK 73762 (NAICS 333415). OSHA activity number 339483638.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Temtrol, INC. — free Get an email when a new federal OSHA severe-injury report for Temtrol, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TEMTROL, INC.
Site address
15 E OKLAHOMA AVE
City
OKARCHE
State
OK
ZIP
73762
Mailing
15 E OKLAHOMA AVE, OKARCHE, OK 73762
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
345
Ownership type
A

10 citations on file for this inspection.

1910.132 F01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 18, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,550 · Current $1,200 Reduced
29 CFR 1910.132(f)(1):  The employer did not provide training to each employee who is required by this section to use personal protection equipment (PPE).    On or about November 13, 2013, and times prior thereto, the employer did not provide adequate training for employees required to use fall protection at heights greater than four (4) feet, including training about the proper care, maintenance and useful life of the fall protection equipment.  This exposed employees to fall hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2550

1910.178 L02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 18, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,550 · Current $1,300 Reduced
29 CFR 1910.178(l)(2)(ii):  The employer did not ensure powered industrial truck training consisted of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operators performance in the workplace.    On or about November 13, 2013, and times prior thereto, employees were allowed to operate forklifts with having only taken a written test to gain their forklift certification from the employer.  This exposed employees to struck-by and/or caught-in/between hazards.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2550

1910.332 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Apr 30, 2014
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety.    On or about November 13, 2013, and times prior thereto, fan balancing area in the Assembly Building; unqualified employees were allowed to balance fans and test low-amp and high-amp fan motors, both using 460 volts.  This exposed employees to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.334 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(c)(1): Unqualified persons performed testing work on electric circuits or equipment.    On or about November 13, 2013, and times prior thereto, unqualified employees were allowed to balance fans and test low-amp and high-amp fan motors, by using 460 volts.  This exposed employees to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 10 3 instances 2 exposed
Issued
Mar 18, 2014
Abate by
Mar 20, 2014
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).     On or about November 13, 2013, and times prior thereto, throughout the Assembly building, employees were allowed to use DeWALT DW268 electric screwdrivers with damaged cords which were connected to extension cords with exposed wires and/or being severely damaged.  This exposed employees to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.334 A02 II

Serious Gravity 10 4 instances 4 exposed
Issued
Mar 18, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There were defects or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service.   On or about November 13, 2013, and times prior thereto, from tool carts located within the Assembly building, employees were allowed to use DeWALT DW268 electric screwdrivers with damaged cords which were connected to extension cords with exposed wires and/or being severely damaged.  This exposed employees to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 18, 2014
Abate by
Mar 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  On or about November 13, 2013, and times prior thereto, employees were allowed to use DeWALT DW268 electric screwdrivers connected to extension cords where the plug-connection from the tool and the extension cord were taped together with electrical tape and/or duct tape.  This exposed employees to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J02 III

Other-than-serious 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Mar 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iii): Daily visual inspections and monthly inspections with a signed certification of record were not performed on hooks.  For the Gaffey 2-ton gantry crane with a 1-ton hoist located in the Assembly Building, Bay 3 area, across from Column 4, east side:  On or about November 13, 2013,  the employer did not ensure daily visual inspections and monthly signed, certified inspections had been performed to ensure there was no deformation or cracks to hooks.  This exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.184 C02

Other-than-serious 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Mar 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.184(c)(2): Slings shall not be shortened with knots or bolts or other makeshift devices.  On or about November 13, 2013, and times prior thereto, a chain sling used to hoist a 350-pound fan motor had a links of the chain wrapped inside a hook to hold the rigging, in addition to, chain slings for the rigging had a bolt and plastic zip tie to shorten the chains.  This exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.184 C14

Other-than-serious 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Mar 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.184(c)(14): Employers must not use slings without affixed and legible identification markings.  On or about November 13, 2013, and times prior thereto, chain slings used to hoist 350-pound fan motors did not have affixed identification tags.  This exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Temtrol, INC.'s full OSHA safety record →