Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OXLITE MANUFACTURING

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of OXLITE MANUFACTURING in 1800 REES ST, BREAUX BRIDGE, LA 70517 (NAICS 332311). OSHA activity number 339485732.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oxlite Manufacturing — free Get an email when a new federal OSHA severe-injury report for Oxlite Manufacturing is published. One employer, no account, unsubscribe in one click.
Site address
1800 REES ST
City
BREAUX BRIDGE
State
LA
ZIP
70517
Mailing
P O BOX 82, LEONVILLE, LA 70551
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
8
Ownership type
A

4 citations on file for this inspection.

1910.134 D01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    On or about 1/21/2014, in the welding area on the northwest side of the facility, the employer allowed employees to weld and grind aluminum without conducting a hazard assessment to determine if respirators were necessary.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1910.252 C01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.252(c)(1)(iii): Local exhaust or general ventilating systems were not provided and arranged to keep the amount of toxic fumes, gases, or dusts below the maximum allowable concentration as specified in 29 CFR 1910.1000:    On or about 1/21/2014, in the welding area on the northwest side of the facility, the employer allowed employees to weld aluminum in order to fabricate aluminum ramps without providing ventilation sufficient to keep the concentration of the respirable fraction of particles not otherwise regulated below the permissible exposure limit of five (5) milligrams per cubic meter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.1000 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9130

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of the respirable fraction of particles not otherwise regulated ("respirable particles") listed in Table Z-1 in excess of the eight (8) hour Time Weighted Average concentration of five (5) milligrams per cubic meter:   The employer does not ensure that no employees are exposed to an airborne concentration of respirable particles in excess of five (5) milligrams per cubic meter as an eight (8) hour time weighted average (TWA).  This violation occurred on 1/21/2014, in the welding area of the facility, when an employee was exposed to an eight-hour time weighted average concentration of eleven and six tenths (11.6) milligrams per cubic meter of respirable particles when sampled for 468 minutes.  Zero exposure was assumed for the un-sampled 12 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1000 E

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Where engineering and administrative controls were not feasible to achieve full compliance with paragraphs (a) through (d) of this section, the employer did not ensure respirator use in compliance with 29 CFR 1910.134:  On or about 1/21/2014, in the welding area on the northwest side of the facility, the employer allowed employees to weld and grind aluminum in order to fabricate aluminum ramps without requiring the use of respirators where employee exposure was above the permissible exposure limit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Oxlite Manufacturing's full OSHA safety record →