WEST CHAZY, NY ·
OSHA Inspection: AERO PRECISION SHEET METAL, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AERO PRECISION SHEET METAL, LLC in 431 DUQUETTE RD, WEST CHAZY, NY 12992 (NAICS 332313). OSHA activity number 339491870.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AERO PRECISION SHEET METAL, LLC
- Site address
- 431 DUQUETTE RD
- City
- WEST CHAZY
- State
- NY
- ZIP
- 12992
- Mailing
- 431 DUQUETTE RD, WEST CHAZY, NY 12992
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 14
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.134 C01
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $1,360 · Current $1,020 Reduced
9135
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for an employee powdercoating metal parts. The employee was required to wear a full-face, tight-fitting Moldex respirator and no written respiratory protection program was implemented at the worksite.
Recent events (2)
- · I (S) $1020
- · Z (S) $1360
1910.134 E01
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $0 · Current $0
9135
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for an employee powdercoating metal parts. The employee had not been medically evaluated to wear the half-face, tight-fitting Moldex respirator.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 F01
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $0 · Current $0
9135
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for an employee powdercoating metal parts. The employee had not been fit tested to wear the tight-fitting Moldex respirator used for this task.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1026 D01
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $1,700 · Current $1,275 Reduced
0689
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees performing CNC laser cutting stainless steel. (b) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees welding on stainless steel.
Recent events (2)
- · I (S) $1275
- · Z (S) $1700
1910.1026 I01
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $1,700 · Current $1,275 Reduced
0689
General-duty citation text
29 CFR 1910.1026(i)(1): The employer provided washing, eating and drinking areas at a worksite with chromium (VI) exposures; however, this area was not in conformance with the Sanitation standard, 29 CFR 1910.141: (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees working near the welding area. (b) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees who drank, ate lunch, or prepared food in the kitchen.
Recent events (2)
- · I (S) $1275
- · Z (S) $1700
1910.1026 I03 I
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(i)(3)(i): Readily accessible washing facilities capable of removing chromium (VI) from the skin were not provided by the employer at a worksite with chromium (VI) exposures: (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees laser cutting and welding stainless steel.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1026 I04 I
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(i)(4)(i): Employees were allowed to consume food or beverages at a worksite where chromium (VI) was present; however, the employer did not ensure that the eating and drinking areas were maintained as free as practicable of chromium (VI): (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees laser cutting and welding of stainless steel.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1026 L01 III
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $1,700 · Current $1,275 Reduced
0689
General-duty citation text
29 CFR 1910.1026(l)(1)(iii): Employers shall include chromium (VI) in the hazard communication program established to comply with the HCS (� 1910.1200). Employers shall ensure that each employee has access to labels on containers of chromium (VI) and to safety data sheets, and is trained in accordance with the requirements of HCS and paragraph (l)(2) of this section: (a) On or about 12/12/2013 at Aero Precision Sheet Metal, LLC, for employees laser cutting and welding of stainless steel.
Recent events (2)
- · I (S) $1275
- · Z (S) $1700
1910.1200 E01
- Issued
- May 2, 2014
- Abate by
- Jun 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about 12/11/2013 at Aero Precision Sheet Metal, for welders, CNC laser operators, and powdercoaters. Employees used chemicals including but not limited to stainless and cold-rolled steel sheet and TGIC powdercoating.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Aero Precision Sheet Metal, LLC
View Aero Precision Sheet Metal, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332313)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339491870.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.