CHURCH POINT, LA ·
OSHA Inspection: ACADIAN FINE FOODS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ACADIAN FINE FOODS LLC in 329 S MAIN ST, CHURCH POINT, LA 70525 (NAICS 311712). OSHA activity number 339496259.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACADIAN FINE FOODS LLC
- Site address
- 329 S MAIN ST
- City
- CHURCH POINT
- State
- LA
- ZIP
- 70525
- Mailing
- 329 S MAIN ST, CHURCH POINT, LA 70525
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311712
- Employees
- 26
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.178 L01 I
- Issued
- May 6, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $2,800 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 11/19/2013, the employer did not ensure that forklift operators were trained to operate the forklifts at the facility.
Recent events (2)
- · I (S) $2400
- · Z (S) $2800
1910.178 P01
- Issued
- May 6, 2014
- Abate by
- May 16, 2014
- Penalty
- Initial $2,800 · Current $800 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). On or about 11/19/2013, the employer did not ensure that a fork lift used inside of the plant was tagged indicating that it has been removed from service until its operational status was determined. By not tagging the fork lift out of service, any employee could potyentially use the defective equipment.
Recent events (2)
- · I (O) $800
- · Z (S) $2800
1910.305 B02 I
- Issued
- May 6, 2014
- Abate by
- May 16, 2014
- Penalty
- Initial $4,900 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Covers of outlet boxes having holes through which flexible cord pendants passed were not provided with bushings designed for the purpose nor did the holes have smooth, well-rounded surfaces on which the cords could bear. On or about 11/19/2013,the employer did not ensure that flexible cables entering junction boxes through the covers were within bushings as the cable passed through the door. A cable was observed entering a junction box of a conveyor belt section without a bushing which allowed moisture/water to enter the box, potentially creating shorting, arcing and electric shock conditions.
Recent events (2)
- · I (S) $3000
- · Z (S) $4900
1910.305 E01
- Issued
- May 6, 2014
- Abate by
- May 16, 2014
- Penalty
- Initial $4,900 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: On or about 11/29/2013, the employer did not ensure that electrical boxes located on equipment in the Single Serve processing area were able to prevent water and moisture from entering the various boxes. Covers on the electrical boxes listed below allowed water and moisture to enter the boxes due to the gaskets becoming hard and brittle. This condition allowed for the equipment to become energized due tothe water and moisture buildup within. INSTANCES: a) Mobile conveyor belt section. Small junction box on the length side of the belt. b) Large junction box at the end of the Mobile conveyor belt section c) Junction box located on the stainless steel sealer. d) Junction box on the hopper.
Recent events (2)
- · I (S) $3000
- · Z (S) $4900
More inspections at Acadian Fine Foods LLC
View Acadian Fine Foods LLC's full OSHA safety record →
More inspections in this industry (NAICS 311712)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339496259.