On , OSHA opened a complaint safety inspection of WESTERN ARCHITECTURAL IRON COMPANY in 3455 N ELSTON, CHICAGO, IL 60618 (NAICS 238190). OSHA activity number 339498925.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Architectural Iron Company for free Get an email when a new federal OSHA severe-injury report for Western Architectural Iron Company is published. One employer, no account, unsubscribe in one click.
Site address
3455 N ELSTON
City
CHICAGO
State
IL
ZIP
60618
Mailing
3455 N ELSTON, CHICAGO, IL 60618
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
15
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 4, 2013
Abate by
Dec 31, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.212(a)(1): The employer did not ensure that one or more methods of machine guarding was provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, rotating parts, flying chips and sparks:      a)  Production Area (Main Working Station Area)- The Cincinnati Lathe & Tool Co. lathe was not equipped with an enclosure guard for the rotating chuck and a chip guard to contain flying chips and/or sparks.  In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $1600

1910.305 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 4, 2013
Abate by
Dec 31, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.305(b)(2)(i): The employer did not ensure that all pull boxes, junction boxes, and fittings were provided with covers approved for the purpose:   a) Production Area (Lathe/ Air Compressor) - The electrical breaker box to the Air Compressor did not have a cover.   In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.334 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 4, 2013
Penalty
Initial $340 · Current $238 Reduced
29 CFR 1910.334(a)(2)(i): The employer did not ensure that portable cord and plug connected equipment and flexible cord sets (extension cords) were visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) Production Area (Area near Sterling Grinder and Wilton Drill Press)-  An orange extension cord used to power hand tools had damage to the outer jacket/insulation.     No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (O) $238
  • · Z (O) $340

1910.334 A02 II

Other-than-serious 1 instance 1 exposed
Issued
Dec 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): The employer did not ensure that when there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was removed from service until the repairs and tests necessary to render the electric equipment safe had been made:   a) Production Area ( Area near Sterling Grinder and Wilton Drill Press) - An orange extension cord used to power hand tools had damage to the outer jacket/insulation was not removed from service.   No abatement certification or documentation is required for this item.