OSHA Inspection: A-1 DINER LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of A-1 DINER LLC in 340 SAW MILL ROAD, WEST HAVEN, CT 06516 (NAICS 236220). OSHA activity number 339505547.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A-1 Diner LLC for free Get an email when a new federal OSHA severe-injury report for A-1 Diner LLC is published. One employer, no account, unsubscribe in one click.
Establishment
A-1 DINER LLC
Site address
340 SAW MILL ROAD
City
WEST HAVEN
State
CT
ZIP
06516
Mailing
196-60 45TH ROAD, FLUSHING, NY 11358
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
5
Ownership type
Private (A)

10 citations on file for this inspection.

1926.304 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.304(h)(1): Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.  WORKSITE: The saw blade on the Jet model JWTS-10CW2-LFR 10 inch table saw, serial number 03014275, used by employees to cut plywood during the build-out process was missing the blade guard.
Recent events (1)
  • · Z (S) $0

1926.307 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.307(d)(1): "Guarding." Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes.  WORKSITE: The pulleys on the Jet model JWTS-10CW2-LFR 10 inch table saw, serial number 03014275, used by employees to cut plywood during the build-out process was not adequately guarded, exposing employees to the rotating pulleys.
Recent events (1)
  • · Z (S) $0

1926.307 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.307(e)(1)(i): Where both runs of horizontal belts are 7 feet (2.128 m) or less from the floor level, the guard shall extend to at least 15 inches (38.1 cm) above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches (106.68 cm) or less from the floor, the belt shall be fully enclosed.  WORKSITE: The horizontal belt on the Jet model JWTS-10CW2-LFR 10 inch table saw, serial number 03014275, used by employees to cut plywood during the build-out process was not adequately guarded, exposing employee to the ingoing nip point between the belt and pulleys.
Recent events (1)
  • · Z (S) $0

1926.403 E

Other-than-serious 1 instance 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.403(e): Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.  WORKSITE: The power cord on a Dewalt portable hand drill, used by employees during the build-out process was spliced with a flat 3-wire cord.
Recent events (1)
  • · Z (O) $0

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  WORKSITE: The yellow extension cord, used to energize the temporary lights in the main room was missing its ground prong.
Recent events (1)
  • · Z (O) $0

1926.404 F07 IV

Other-than-serious 1 instance 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(7)(iv): Equipment connected by cord and plug. Under any of the conditions described in paragraphs (f)(7)(iv)(A) through (f)(7)(iv)(C) of this section, exposed noncurrent-carrying metal parts of cord- and plug-connected equipment which may become energized shall be grounded:  WORKSITE: The ground wire of the power cord on the Jet model JWTS-10CW2-LFR 10 inch table saw, serial number 03014275, used by employees to cut plywood during the build-out process was not connected to the plug.
Recent events (1)
  • · Z (O) $0

1926.405 A02 II E

Other-than-serious 4 instances 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.  WORKSITE: Temporary lighting used to illuminate the building was missing cages and lights throughout the building.
Recent events (1)
  • · Z (O) $0

1926.405 A02 II F

Other-than-serious 4 instances 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.  WORKSITE: Temporary lighting used to illuminate the building was hung by the wiring in the ceiling.
Recent events (1)
  • · Z (O) $0

1926.405 G01 III

Other-than-serious 2 instances 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(1)(iii): Prohibited uses. Unless necessary for a use permitted in paragraph (g)(1)(i) of this section, flexible cords and cables shall not be used:  WORKSITE: Two yellow extension cords, used to energize equipment throughout the building were attached to the building and were run through doorways.
Recent events (1)
  • · Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Feb 11, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  WORKSITE: The power cord on the Jet model JWTS-10CW2-LFR 10 inch table saw, serial number 03014275, was missing the outer sheathing at the plug.
Recent events (1)
  • · Z (O) $0

View A-1 Diner LLC's full OSHA safety record →