EL PASO, TX —
OSHA Inspection: HP CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HP CONSTRUCTION in 12404 SOMBRA ALRGRE DR., EL PASO, TX 79938 (NAICS 238160). OSHA activity number 339512691.
Where did this inspection happen?
- Establishment
- HP CONSTRUCTION
- Site address
- 12404 SOMBRA ALRGRE DR.
- City
- EL PASO
- State
- TX
- ZIP
- 79938
- Mailing
- 360 BURKETT, CLINT, TX 79836
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $15400.00 · Current $7200.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: On or about December 6, 2013, in front the house under construction one employee was observed working without utilizing any form a fall protection system. The employee was exposed to a fall hazard of greater than six feet. HP Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 799221, citation number 01, item number 001 and was affirmed as a final order on January 17, 2013, with respect to a workplace located at 3180 Hidden Creek, El Paso, TX 79938.
Recent events (2)
- — I (R) $7200
- — Z (R) $15400
1926.405 G02 III
- Issued
- Abate by
- Penalty
- Initial $1320.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: On or about December 6, 2013, on the right side of the house under construction, employees were using a 100-foot orange/black 14-AWG (2.08mm2) extension cord that had been repaired (spliced) after being cut in half and was significantly altered because of the repair. Employees were exposed to shock hazards.
Recent events (2)
- — I (S) $800
- — Z (S) $1320
More inspections at HP CONSTRUCTION
CANUTILLO, TX—2024-01-10 00:00:00
HP CONSTRUCTION
EL PASO, TX—2017-09-22 00:00:00
HP CONSTRUCTION
EL PASO, TX—2017-03-08 00:00:00
HP CONSTRUCTION
EL PASO, TX—2017-01-26 00:00:00
HP CONSTRUCTION
EL PASO, TX—2017-01-11 00:00:00
HP CONSTRUCTION
View HP CONSTRUCTION's full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339512691.