Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: GEORGIA BOTTLE COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GEORGIA BOTTLE COMPANY, INC. in 1001 HOLLOWAY DR., QUITMAN, GA 31643 (NAICS 326160). OSHA activity number 339513665.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Georgia Bottle Company, INC. for free Get an email when a new federal OSHA severe-injury report for Georgia Bottle Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1001 HOLLOWAY DR.
City
QUITMAN
State
GA
ZIP
31643
Mailing
1001 HOLLOWAY DR., QUITMAN, GA 31643
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326160
Employees
22
Ownership type
Private (A)

13 citations on file for this inspection.

1910.27 D03

Serious Gravity 5 1 instance 2 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.27(d)(3): The side rails of through or side-step ladder extensions did not extend 3 1/2 feet above paraphets and landings:  a)  Exterior rear of building, on or about December 11, 2013, employees used a fixed ladder to gain access to the top of the silo.  The ladder did not extend 42 inches above the top of the silo, exposing employees to a fall hazard of 8 feet.   ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $1600

1910.147 C01

Serious Gravity 10 1 instance 6 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Facility, on or about December 11, 2013, the employer did not develop a lock out /tag out program for employees who perform maintenance and repairs on equipment, such as grinding machines and blow mold machines  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $2800

1910.212 A01

Serious Gravity 10 9 instances 5 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)    Blow mold production area,  on or about  December 4, 2013, injection blow mold machine #2 was not adequately guarded in that the gate guards on the sides of the machine could be easily opened without special tools, and was not interlocked to automatically shut the machine down when the gates were opened, exposing employees to a pinch point hazard.       b)      Blow mold production area,  on or about  December 4, 2013, Impco injection blow mold machine #2 was not adequately guarded in that the gate guards on the sides of the machine could be easily opened without special tools, and was not interlocked to automatically shut the machine down when the gates were opened, exposing employees to a pinch point hazard.  c)     Blow mold production area, on or about December 4, 2013, Rocheleau injection blow mold machine #5 was not adequately guarded in that the area where the two halves of the mold come together was not guarded on top, exposing employees to a pinch point hazard.    d)    Blow mold production area, on or about December 4, 2013, injection blow mold machine #6 was not adequately guarded in that the area where the two halves of the mold come together was not guarded on top, exposing employees to a pinch point hazard.    e)     Blow mold production area, on or about December 4, 2013, injection blow mold machine #7 was not adequately guarded in that the area where the two halves of the mold come together in that the gate guards on the sides of the machine could be easily opened without special tools, and was not interlocked to automatically shut the machine down when the gates were opened, exposing employees to a pinch point hazard., exposing employees to a pinch point hazard.    f)      Blow mold production area, on or about December 4, 2013, injection blow mold machine #11 was not adequately guarded in that the area where the two halves of the mold come together was not guarded on top, exposing employees to a pinch point hazard.      g)    Blow mold production area, on or about December 4, 2013, Rosade blow mold machine #12 was not adequately guarded in that the area where the two halves of the mold come together was not guarded on top, exposing employees to a pinch point hazard.      h) Behind Blow Mold machine #12, the area where the conveyor belt went over the bottom drum      near the floor was not guarded, exposing employees to an in-running nip point hazard.    i) Blow Mold machine area, on or about January 30, 2014, the fire (flame) from the flamer machine was not guarded, exposing employees to a burn hazard.    ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED.
Recent events (1)
  • · Z (S) $2800

1910.219 E03 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) of this section:  a) By blow mold machines #9 and #11, on or about December 4, 2013, the belt drive for the conveyor was not guarded, exposing employees to an in-running nip point hazard.   ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $2800

1910.253 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 13, 2014
Abate by
Jun 9, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or:  a)  By maintenance shop, on or about December 4, 2013,  oxygen and acetylene cylinders were stored together, exposing employees to a fire hazard.   ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $2800

1910.253 A03

Serious Gravity 5 1 instance 3 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved:  a) By maintenance shop, on or about January 30, 2014, the gauges on the oxygen and acetylene regulators did not have protective lens in place.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 10 1 instance 5 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a)  By blow mold machine #9 , on or about January 30, 2014, an electrical box containing a switch, did not have a faceplate, exposing employees to an electrical shock hazard.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $2800

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Production Area, on or about December 4, 2014, an electrical connection on the side of an electrical motor for a conveyor belt by blow mold machines #9 and #11 did not have a cover and had exposed energized wires, exposing employees to an electrical shock/burn hazard.     ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 2 exposed
Issued
May 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) By exit door by machine #1, on or about January 30, 2014, access to and working area around two breaker panels was blocked by drums of hydraulic oil exposing employees to an electrical shock hazard.  ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (1)
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 5 2 instances 5 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a)  Production area, on or about December 4, 2013, the wires from an electrical motor were spliced to an electrical cord outside of an enclosure by blow mold machines #9 and #11, exposing employees to electrical hazards.   b) Production area, on or about December 4, 2013, the wires from an electrical motor were spliced to an electrical cord outside of an enclosure on the trimmer behind blow mold machine #9, exposing employees to electrical hazards.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 5 7 instances 6 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  Production area, on or about December 4, 2013, The electrical  disconnect box on the side of the #2 blow mold machine had an unused opening on the side, exposing employees to an electrical shock hazard.     b) Production area, on or about January 30, 2014, the electrical box on the side of the #4 blow mold machine had an unused opening on the side of an electrical box, exposing employees to an electrical shock hazard.   c) Production area, on or about January 30, 2014, an electrical box on the side of the #5 Rocheleau blow mold machine had an unused opening on the top of the electrical box, exposing employees to an electrical shock hazard.     d) Production area, on or about January 30, 2014, the electrical box on the side of the #6 Rocheleau blow mold machine had an unused opening on the front of the electrical control box and 2 openings in the electrical box under the electrical disconnect , exposing employees to an electrical shock hazard.     e) Production area, on or about January 30,  2014, the electrical receptacle  box hanging down behind the #6 Rocheleau blow mold machine had unused openings on the sides of the box, exposing employees to an electrical shock hazard.     f) Production area, on or about January 30, 2014, the electrical breaker panel by the # 13 blow mold machine had an unused opening on the side of the electrical box, exposing employees to an electrical shock hazard.   g) Production area, on or about January 30, 2014, the electrical receptacle box by the flamer had an unused opening on the side of the electrical box, exposing employee to an electrical shock hazard.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $0

1910.305 D02

Serious Gravity 5 2 instances 4 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front:  a) By exit door by blow mold machine #1, on or about January 30, 2014, an electrical breaker panel was not dead front and had an opening in the face plate, exposing employees to an electrical shock hazard.   b) By blow mold machine #14, on or about January 30, 2014, an electrical breaker panel was not dead front and had an opening in the face plate, exposing employees to an electrical shock hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
May 13, 2014
Abate by
Jun 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) Production area, on or about December 4, 2013, The plug on the end of a flexible cord used to energize a trimmer did not have a proper strain relief, exposing employees to electrical hazards.   ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • · Z (S) $0

View Georgia Bottle Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339513665.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.