Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED INDUSTRIAL SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANCED INDUSTRIAL SERVICES, INC. in 400 PARK DRIVE, CARLISLE, PA 17015 (NAICS 237110). OSHA activity number 339514259.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Industrial Services, INC. — free Get an email when a new federal OSHA severe-injury report for Advanced Industrial Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
400 PARK DRIVE
City
CARLISLE
State
PA
ZIP
17015
Mailing
3250 NORTH SUSQUEHANNA TRAIL, YORK, PA 17406
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 5, 2014
Abate by
Mar 4, 2014
Penalty
Initial $6,300 · Current $4,725 Reduced

Hazardous substances S777

29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c):    (a) Trench at North Niagara Tower, PPG Industries, Inc., 400 Park Drive, Carlisle, Pennsylvania - On December 5, 2013, an employee entered the south end of the trench, 67 feet long, 7 feet wide, with a depth of 5 feet, dug in Type B soil, to place a section of the new 10-inch water line.  Part of the east wall at the south end of the trench had already collapsed and had additional tension cracks.  Also, the soil had a high moisture content due to rainy conditions and due to water from the cooling water system leaking and running into the soil.  A homemade shoring system consisting of two wood panels 16 feet long and 4 feet wide, laid length-wise, with one panel on the east wall and one panel on the west wall at the south end of the trench, with two Dayton telescopic support braces placed one above the other across the width of the trench and at the middle of the two wood panels, constituted the only cave-in protection in the trench.  This homemade support system did not comply with paragraph (c) in that a registered professional engineer did not design and approve the support system and no tabulated data existed for the system, exposing employees to the hazard of a cave-in.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $4725
  • — Z (S) $6300

1926.21 B02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Feb 5, 2014
Abate by
Mar 4, 2014
Penalty
Initial $0 · Current $0

Hazardous substances S777

29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:  (a) Trench at North Niagara Tower, PPG Industries, Inc., 400 Park Drive, Carlisle, Pennsylvania - The employer did not provide employees with training on trenching and excavation safety, and on December 5, 2013, an employee entered the south end of the trench, 67 feet long, 7 feet wide, with a depth of 5 feet, dug in Type B soil, to place a section of the new 10-inch water line.  Part of the east wall at the south end of the trench had already collapsed and had additional tension cracks.  Also, the soil had a high moisture content due to rainy conditions and due to water from the cooling water system leaking and running into the soil.  A homemade shoring system consisting of two wood panels 16 feet long and 4 feet wide, laid length-wise, with one panel on the east wall and one panel on the west wall at the south end of the trench, with two Dayton telescopic support braces placed one above the other across the width of the trench and at the middle of the two wood panels, constituted the only cave-in protection in the trench.  This homemade support system did not comply with paragraph (c) in that a registered professional engineer did not design and approve the support system and no tabulated data existed for the system, exposing employees to the hazard of a cave-in.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2014
Abate by
Mar 4, 2014
Penalty
Initial $2,700 · Current $2,700
29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed:  (a) Trench at North Niagara Tower, PPG Industries, Inc., 400 Park Drive, Carlisle, Pennsylvania - An employee used a Werner 8-foot fiberglass stepladder in the closed position to access the trench, exposing the employee to the hazard of falling to a lower level, on or about December 5, 2013.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $2700

View Advanced Industrial Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339514259.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.