Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WELLBORN CABINET, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WELLBORN CABINET, INC. in 38669 HIGHWAY 77, ASHLAND, AL 36251 (NAICS 337110). OSHA activity number 339516239.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wellborn Cabinet, INC. for free Get an email when a new federal OSHA severe-injury report for Wellborn Cabinet, INC. is published. One employer, no account, unsubscribe in one click.
Site address
38669 HIGHWAY 77
City
ASHLAND
State
AL
ZIP
36251
Mailing
38669 HIGHWAY 77, ASHLAND, AL 36251
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
850
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 C

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 3, 2014
Penalty
Initial $2,250 · Current $1,350 Reduced
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc:   (a) On or about 12/05/13 -Truck shop, The 100' by 4' pit was left open and employees were not protected from falls.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $2250

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 15, 2014
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.147(c)(7)(i):  Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    (a)    On or about 12/05/13 - Door Department, TEN 0087,  employees were not trained in lockout/tag out procedures.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.147 D03

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 15, 2014
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:   (a)    On or about 12/05/13 - Door Department, TEN 0087,  the employees did not lock out the tenoning machine while changing out the cutting heads.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.304 G05

Serious Gravity 1 6 instances 4 exposed
Issued
Apr 3, 2014
Abate by
Apr 15, 2014
Penalty
Initial $2,250 · Current $1,350 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    (a)  On or about 12/06/13  in the Rough Mill Department, the cords used to service six (6) Air King High Velocity fans had missing grounding prongs.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $2250

View Wellborn Cabinet, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339516239.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.