OSHA Inspection: HOFFMASTER GROUP INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of HOFFMASTER GROUP INC in 2920 N. MAIN ST., OSHKOSH, WI 54901 (NAICS 322291). OSHA activity number 339521783.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hoffmaster Group INC for free Get an email when a new federal OSHA severe-injury report for Hoffmaster Group INC is published. One employer, no account, unsubscribe in one click.
Site address
2920 N. MAIN ST.
City
OSHKOSH
State
WI
ZIP
54901
Mailing
P.O. BOX 2038, OSHKOSH, WI 54903
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322291
Employees
490
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2014
Abate by
Apr 25, 2014
Penalty
Initial $4,250 · Current $1,700 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    a) On or about December 16, 2013 the indoor filter media-type dust collector units (Kelva systems) used for collecting combustible paper dust were not provided with a means of:     i.  Explosion protection for the dust collectors  ii. Fire protection for the dust collectors  iii. Deflagration (flame front) propagation protection between the dust collector units and the upstream process equipment
Recent events (2)
  • · I (S) $1700
  • · Z (S) $4250

1910.307 C

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2014
Abate by
Apr 25, 2014
Penalty
Initial $7,000 · Current $4,250 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous Class II locations were not intrinsically safe, approved for the hazardous Class II location, or safe for the hazardous Class II location:    a) Employees were exposed to hazards associated with unapproved electrical equipment in a Class II hazardous area in the napkin converting area of the facility. A motor for a conveyor and an electrical outlet was found in the Class II area of the facility.     ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • · I (S) $4250
  • · Z (S) $7000

View Hoffmaster Group INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339521783.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.