OSHA Inspection: MGB CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MGB CONSTRUCTION, INC. in 1801 WP BALL BLVD., SANFORD, FL 32771 (NAICS 238140). OSHA activity number 339528135.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MGB Construction, INC. — free Get an email when a new federal OSHA severe-injury report for MGB Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1801 WP BALL BLVD.
City
SANFORD
State
FL
ZIP
32771
Mailing
3221 SOUTH SEMORAN BLVD #10, ORLANDO, FL 32822
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 2, 2014
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:  a. Scaffold east area - ladder used for access to the welded frame scaffold was partially taken down and did not extend for completed access to the second level; employees used an endframe for access and were exposed up to a 13' 9" fall hazard.  Violation observed on or about 12/18/13.
Recent events (1)
  • — Z (S) $1020

1926.451 G04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 2, 2014
Abate by
Jan 8, 2014
Penalty
Initial $2,040 · Current $2,040
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms:     a. Scaffold east and south walls - single cross bracing sections were used on open sides of platforms as both a mid and top rail during masonry operations and exposed employee(s) up to a 13' 9" fall hazard on a welded frame scaffold.  Violation observed on or about 12/18/13.
Recent events (1)
  • — Z (S) $2040

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Jan 2, 2014
Abate by
Feb 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a. Mixing area - employees that used 3M 8210 N95 dust masks during masonry operations were not provided the information contained in Appendix D of 29 CFR 1910.134.  Violation observed on or about 12/18/13.