OSHA Inspection: M & M WOOD PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M & M WOOD PRODUCTS, INC. in 159 LAKE STREET, MORRIS RUN, PA 16939 (NAICS 321920). OSHA activity number 339529752.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & M Wood Products, INC. — free Get an email when a new federal OSHA severe-injury report for M & M Wood Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
159 LAKE STREET
City
MORRIS RUN
State
PA
ZIP
16939
Mailing
P.O. BOX 207, MORRIS RUN, PA 16939
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
14
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 14 exposed
Issued
Feb 7, 2014
Abate by
Feb 20, 2014
Penalty
Initial $1,600 · Current $1,040 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:      a) Production: Wood dust and debris from the pallet production process has accumulated on and around the machinery and equipment while employees work in this area, potentially exposing employees to injury, observed on or about December 20, 2013.       Abatement Certification Required
Recent events (2)
  • — I (S) $1040
  • — Z (S) $1600

1910.147 C04 I

Serious Gravity 5 1 instance 14 exposed
Issued
Feb 7, 2014
Abate by
Feb 20, 2014
Penalty
Initial $1,600 · Current $1,040 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Production: The employer did not develop, document and utilize procedures for the control of potentially hazardous energy while employees were engaged in service and maintenance activities of the mulit cross-cut saw, observed on or about December 20, 2013.    Abatement Certification Required.    ABATEMENT NOTE:    The procedures should clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, the means to enforce compliance including but not limited to:    A specific statement of the intended use of the procedure.    Specific procedural steps for shutting down, isolating, blocking and servicing machines or equipment to control hazardous energy.    Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.    Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices and other energy control measures.
Recent events (2)
  • — I (S) $1040
  • — Z (S) $1600

1910.147 C07 I

Serious Gravity 5 1 instance 14 exposed
Issued
Feb 7, 2014
Abate by
Mar 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   a) Production:  On or about December 20, 2013, the employer did not provide training to ensure that the purpose and function of the energy control program was understood and that the knowledge and skills required for the safe application, usage and removal of the energy controls are acquired by maintenance employees, equipment operators and other employees.    Abatement certification required.   ABATEMENT NOTE:    Training must be tailored to the requirements of the job responsibility:   Employees conducting servicing and maintenance on equipment must be trained as authorized employees as per 29 CFR 1910.147(c)(7)(i)(A)   Employees operating equipment which may be locked out must be trained as affected employees as per 29 CFR 1910.147(c)(7)(i)(B)   All other employees must be trained as per 29 CFR 1910.147(c)(7)(i)(C)
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 14 exposed
Issued
Feb 7, 2014
Abate by
Feb 27, 2014
Penalty
Initial $1,200 · Current $780 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:      a) Production:  Sufficient access and working space was not provided and maintained about all circuit breakers and breaker panels to permit ready and safe operation and maintenance of this equipment. Pallets and other debris were stored in front of the electrical panels impeding access to them thereby exposing employees to injury, observed on or about December 20, 2013.                                                          ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $780
  • — Z (S) $1200

1910.242 B

Repeat Gravity 1 1 instance 14 exposed
Issued
Feb 7, 2014
Abate by
Feb 27, 2014
Penalty
Initial $2,400 · Current $1,560 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 psi:       a) Production:  Compressed air was used by employees to blow wood dust from the wooden pallets and to remove dust from their clothing at more than 30 psi, exposing employees to possibly bodily injury, on or about December 20, 2013.       M & M Wood Products was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.242(b), which was contained in OSHA inspection number 314160797 Citation Number 01, Item number 005, and was affirmed as a final order on February 18, 2011, with respect to a workplace located at 159 Lake Street, Morris Run, PA 16939.                                                             ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • — I (R) $1560
  • — Z (R) $2400

View M & M Wood Products, INC.'s full OSHA safety record →