OSHA Inspection: ZIMMERMAN MARINE INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ZIMMERMAN MARINE INC in 18691 GENERAL PULLER HIGHWAY, DELTAVILLE, VA 23043 (NAICS 336612). OSHA activity number 339530073.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Zimmerman Marine INC — free Get an email when a new federal OSHA severe-injury report for Zimmerman Marine INC is published. One employer, no account, unsubscribe in one click.
Site address
18691 GENERAL PULLER HIGHWAY
City
DELTAVILLE
State
VA
ZIP
23043
Mailing
59 HERON POINT ROAD, CARDINAL, VA 23025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.304 A02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 3, 2014
Abate by
Feb 7, 2014
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.304(a)(2): Polarity of connections. No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity.    a.)    Zimmerman Marine Inc., Carpenter Shop: On or about 12/17/13, two 120 volt wall receptacles installed on the same branch circuit were wired with their hot and neutral wires reversed, as a result, created a potential shock hazard to employees.
Recent events (2)
  • — I (S) $892.5
  • — Z (S) $1785

1910.304 B03 II A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 3, 2014
Penalty
Initial $1,517 · Current $759 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel shall have ground-fault circuit-interrupter protection for personnel.    a.)    Zimmerman Marine Inc., service Bay: On or about 12/17/13, a device capable of providing ground-fault circuit interrupter protection was not used when two extension cords were connected together and plugged into a wall outlet to supply power to a portable vacuum cleaner, thereby exposed employee to a potential shock hazard.     Note 1 to paragraph (b)(3)(ii)(A) of this section: A cord connector on an extension cord set is considered to be a receptacle outlet if the cord set is used for temporary electric power.  Note 2 to paragraph (b)(3)(ii)(A) of this section: Cord sets and devices incorporating the required ground-fault circuit-interrupter that are connected to the receptacle closest to the source of power are acceptable forms of protection.
Recent events (2)
  • — I (S) $758.5
  • — Z (S) $1517

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
Jan 3, 2014
Abate by
Feb 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."  a.) Zimmerman Marine Inc., Service Bay: On or about 12/17/13, the exit door was not marked by a sign reading "Exit".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Zimmerman Marine INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339530073.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.