Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMPLEAT STAIR CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMPLEAT STAIR CO., INC. in 3704 KENNESAW SOUTH INDUSTRIAL DR, KENNESAW, GA 30144 (NAICS 321918). OSHA activity number 339530354.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Compleat Stair CO., INC. — free Get an email when a new federal OSHA severe-injury report for Compleat Stair CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
3704 KENNESAW SOUTH INDUSTRIAL DR
City
KENNESAW
State
GA
ZIP
30144
Mailing
3704 KENNESAW SOUTH INDUSTRIAL DR, KENNESAW, GA 30144
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
32
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 2 exposed
Issued
Feb 7, 2014
Abate by
Mar 6, 2014
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a) Woodworking shop: Employees were exposed to mechanical, pneumatic, and electrical energy hazards while performing maintenance and servicing on CNC milling machines. There were no written procedures in place to isolate the hazardous energy sources and not all employees were trained.
Recent events (2)
  • — I (O) $2100
  • — Z (S) $4200

1910.212 B

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 7, 2014
Abate by
Mar 6, 2014
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    (a) Woodworking shop - Employees were exposed to struck-by hazards, as the Delta electric drill press, S/N 9303, was not anchored to the floor to prevent walking while in operation.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.213 L02

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 7, 2014
Abate by
Mar 6, 2014
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.213(l)(2): Boring bits where not provided with guards that would enclose all portions of the bit and chuck above the material being worked.     (a) Woodworking shop - The employer did not provide a bit or chuck guard for a Delta electric drill press, S/N 9303. Employees were exposed to lacerations and fractures from the rotating parts.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.132 D02

Other-than-serious 1 instance 3 exposed
Issued
Feb 7, 2014
Abate by
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2):   The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  a) Woodworking shop: The employer did not document that a workplace hazard assessment had been performed to facilitate PPE selection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Feb 7, 2014
Abate by
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) Woodworking shop: Employees who were voluntarily using N-95 type respirators for wood dust particles, were not provided with information on respiratory protection such as, but not limited to, proper usage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) Wood shop - A ground pin was missing from the extension cord that was providing power to a Rigid, Model R32021, circular saw.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Compleat Stair CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339530354.