KENNESAW, GA —
OSHA Inspection: COMPLEAT STAIR CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COMPLEAT STAIR CO., INC. in 3704 KENNESAW SOUTH INDUSTRIAL DR, KENNESAW, GA 30144 (NAICS 321918). OSHA activity number 339530354.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPLEAT STAIR CO., INC.
- Site address
- 3704 KENNESAW SOUTH INDUSTRIAL DR
- City
- KENNESAW
- State
- GA
- ZIP
- 30144
- Mailing
- 3704 KENNESAW SOUTH INDUSTRIAL DR, KENNESAW, GA 30144
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 32
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C01
- Issued
- Feb 7, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) Woodworking shop: Employees were exposed to mechanical, pneumatic, and electrical energy hazards while performing maintenance and servicing on CNC milling machines. There were no written procedures in place to isolate the hazardous energy sources and not all employees were trained.
Recent events (2)
- — I (O) $2100
- — Z (S) $4200
1910.212 B
- Issued
- Feb 7, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Woodworking shop - Employees were exposed to struck-by hazards, as the Delta electric drill press, S/N 9303, was not anchored to the floor to prevent walking while in operation.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.213 L02
- Issued
- Feb 7, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.213(l)(2): Boring bits where not provided with guards that would enclose all portions of the bit and chuck above the material being worked. (a) Woodworking shop - The employer did not provide a bit or chuck guard for a Delta electric drill press, S/N 9303. Employees were exposed to lacerations and fractures from the rotating parts.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.132 D02
- Issued
- Feb 7, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): a) Woodworking shop: The employer did not document that a workplace hazard assessment had been performed to facilitate PPE selection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 I
- Issued
- Feb 7, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Woodworking shop: Employees who were voluntarily using N-95 type respirators for wood dust particles, were not provided with information on respiratory protection such as, but not limited to, proper usage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Feb 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Wood shop - A ground pin was missing from the extension cord that was providing power to a Rigid, Model R32021, circular saw.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Compleat Stair CO., INC.
View Compleat Stair CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339530354.