KENNESAW, GA —
OSHA Inspection: COMPLEAT STAIR CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMPLEAT STAIR CO., INC. in 3704 KENNESAW S INDUSTRIAL DR NW, KENNESAW, GA 30144 (NAICS 321918). OSHA activity number 346458409.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPLEAT STAIR CO., INC.
- Site address
- 3704 KENNESAW S INDUSTRIAL DR NW
- City
- KENNESAW
- State
- GA
- ZIP
- 30144
- Mailing
- 3704 KENNESAW S INDUSTRIAL DR NW, KENNESAW, GA 30144
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.213 A13
- Issued
- Jul 13, 2023
- Abate by
- Aug 10, 2023
- Penalty
- Initial $6,641 · Current $3,985 Reduced
General-duty citation text
29 CFR 1910.213(a)(13): Revolving double arbor saws were not fully guarded in accordance with all the requirements for circular crosscut saws or with all the requirements for circular ripsaws, according to the kind of saws mounted on the arbors. a) Production Floor, near band saw: On or about January 24, 2023, and at times prior, the employer exposed employees to amputation hazards in that the employer did not provide effective point of operation guarding on the Spline cutter machine.
Recent events (2)
- — I (S) $3984.6
- — Z (S) $6641
1910.305 B01 I
- Issued
- Jul 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) Shop Floor: On or about January 24, 2023, and times prior, the employer exposed employees to electrical shock hazards, in that abrasion protection was not provided for electrical conductors at the point where the conductors entered the bottom of the 4-inch by 4-inch electrical box which was mounted to a wooden work bench and housed electrical receptacles used by employees to supply power to equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Jul 13, 2023
- Abate by
- Aug 10, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Shop Floor: On or about January 24, 2023, and times prior, the employer exposed employees to electrical shock hazards, in that an unused opening was not closed on the bottom of the 4-inch by 4-inch electrical box which was mounted to a wooden work bench and housed electrical receptacles used by employees to supply power to equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jul 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Shop Floor: On or about January 24, 2023, and times prior, the employer exposed employees to electrical shock hazards, in that strain relief was not provided to electrical conductors entering the bottom of the 4-inch by 4-inch electrical box which was mounted to a wooden work bench and housed electrical receptacles used by employees to supply power to equipment. b) Shop Floor: On or about January 24, 2023, and times prior, the employer exposed employees to electrical shock hazards, in that strain relief was not provided to electrical conductors entering the bottom of a wall mounted, 240 volt junction box supplying power to the band saw used by employees in the manufacturing of stair components.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Compleat Stair CO., INC.
View Compleat Stair CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346458409.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.