Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WHITE CASTLE ROOFING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WHITE CASTLE ROOFING in 6919 O STREET, LINCOLN, NE 68510 (NAICS 238160). OSHA activity number 339534992.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch White Castle Roofing — free Get an email when a new federal OSHA severe-injury report for White Castle Roofing is published. One employer, no account, unsubscribe in one click.
Site address
6919 O STREET
City
LINCOLN
State
NE
ZIP
68510
Mailing
PO BOX 22133, LINCOLN, NE 68502
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.502 H01 III

Serious Gravity 10 3 instances 3 exposed
Issued
Jan 31, 2014
Abate by
Mar 11, 2014
Penalty
Initial $5,390 · Current $2,700 Reduced
29 CFR 1926.502(h)(1)(iii): The safety monitor wan not on the same walking/working surface and within visual sighting distance of the employee being monitored.    The employer failed to protect employees from potential fall hazards associated with roofing a low slope commercial facility roof with a ground to eave height over 6'.  The most recent example of this was found on the job site located at 6919 O Street, Lincoln, NE 68510 where the employer had 3 employees installing the membrane and drains on the awnings in the front of the new Best Buy store they are contracted to build without the benefit of any form of fall protection system in place.  The working surface on the awning was less than 50' x 50' and ground to eave is approximately 11'4".  Acceptable forms of fall protection include but are not limited to:            i.    Fall arrest or restraint systems.         ii.   Guardrail system.         iii.   Safety nets.         iv.   A dedicated monitor positioned on the same working surface as the exposed employees.          v.   Catch platform equipped with guard rail system and positioned within 14" of the edge and no more than 2' below the edge.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $5390

View White Castle Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339534992.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.