Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BENNETT BUILDING SYSTEMS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BENNETT BUILDING SYSTEMS, LLC in 1660 DIXON AIRLINE ROAD, AUGUSTA, GA 30906 (NAICS 332311). OSHA activity number 339537086.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bennett Building Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Bennett Building Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1660 DIXON AIRLINE ROAD
City
AUGUSTA
State
GA
ZIP
30906
Mailing
1660 DIXON AIRLINE ROAD, AUGUSTA, GA 30906
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
65
Ownership type
A

6 citations on file for this inspection.

1910.95 D01

Serious Gravity 10 1 instance 30 exposed
Issued
Apr 29, 2014
Penalty
Initial $7,000 · Current $4,000 Reduced

Hazardous substances 8111

29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:   Fabrication Department-In the manufacturing of sheds, employees in the production area were exposed to noise levels between 86-98 dBA.  Noise monitoring to determine the levels of noise employees were exposed to had not been conducted, on or about 01/14/14.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $7000

1910.95 G01

Serious Gravity 10 5 instances 30 exposed
Issued
Apr 29, 2014
Abate by
Jul 1, 2014
Penalty
Initial $7,000 · Current $3,500 Reduced

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:   a) In the fabrication area, an employee working on wall build was exposed to noise at a time-weighted average (TWA) of 97.6 dBA.  An audiometric testing program was not maintained for the temporary employees.  The sample was obtained from a 443 minute period.  Zero exposure was assumed for the 37 minute unsampled period, on or about 1/14/14.   b) In the fabrication area, an employee working on bottom metal was exposed to noise at a time-weighted average (TWA) of 95.2 dBA.  An audiometric testing program was not maintained for the employees.  The sample was obtained from a 445 minute period.  Zero exposure was assumed for the 35 minute unsampled period, on or about 1/14/14.   c) In the fabrication area, an employee working on wall build was exposed to noise at a time-weighted average (TWA) of 94.05 dBA.  An audiometric testing program was not maintained for the employees.  The sample was obtained from a 414 minute period.  Zero exposure was assumed for the 66 minute unsampled period, on or about 1/14/14.   d) In the fabrication area, an employee working on top metal was exposed to noise at a time-weighted average (TWA) of 86.3 dBA.  An audiometric testing program was not maintained for the employees.  The sample was obtained from a 425 minute period.  Zero exposure was assumed for the 55 minute unsampled period, on or about 1/14/14.   e) In the welding area, an employee welding was exposed to noise at a time-weighted average (TWA) of 88 dBA.  An audiometric testing program was not maintained for the temporary employees.  The sample was obtained from a 442 minute period.  Zero exposure was assumed for the 38 minute unsampled period, on or about 2/05/14.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.95 K01

Serious Gravity 10 5 instances 30 exposed
Issued
Apr 29, 2014
Abate by
Jun 12, 2014
Penalty
Initial $7,000 · Current $3,500 Reduced

Hazardous substances 8111

29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k):     a) In the fabrication area, an employee working on wall build was exposed to noise at a time-weighted average (TWA) of 97.6 dBA.  The temporary employee did not receive noise training in accordance with this section, on or about 1/14/14.   b) In the fabrication area, an employee working on bottom metal was exposed to noise at a time-weighted average (TWA) of 95.2 dBA.  The employee did not receive noise training in accordance with this section, on or about 1/14/14.   c) In the fabrication area, an employee working on wall build was exposed to noise at a time-weighted average (TWA) of 94.05 dBA.  The employee did not receive noise training in accordance with this section, on or about 1/14/14.   d) In the fabrication area, an employee working on top metal was exposed to noise at a time-weighted average (TWA) of 86.3 dBA.  The temporary employee did not receive noise training in accordance with this section, on or about 1/14/14.   e) In the welding area, an employee welding was exposed to noise at a time-weighted average (TWA) of 88 dBA.  The temporary employee did not receive noise training in accordance with this section, on or about 2/5/14.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.252 B02 III

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 29, 2014
Abate by
May 21, 2014
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) Main Welding Shop-The adjacent employees were exposed to welding rays hazard.   The employer did not utilize protective welding screens and/or shields in areas adjacent to where welding work was being performed, on or about December 17, 2013.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3000

1910.1200 E01

Other-than-serious 1 instance 10 exposed
Issued
Apr 29, 2014
Abate by
Jun 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Employees working with hazardous chemicals such as, but not limited to, galvanized steel, welding rods, latex paint, and wood were exposed to inhalation and skin contact hazards.  The employer failed to ensure a written hazard communication program was developed and implemented prior to chemical use, on or about December 17, 2013.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H03 IV

Other-than-serious 1 instance 10 exposed
Issued
Apr 29, 2014
Abate by
Jun 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information:  Employees working with hazardous chemicals such as, but not limited to, galvanized steel, welding rods, latex paint, and wood were exposed to inhalation and skin contact hazards.  The employer failed to ensure all employees were trained on the new label elements (pictograms) and SDS format, on or about December 17, 2013.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bennett Building Systems, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339537086.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.