Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: RAYMOND BUILDING SUPPLY CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAYMOND BUILDING SUPPLY CORP in 7751 BAYSHORE RD, NORTH FORT MYERS, FL 33917 (NAICS 444190). OSHA activity number 339541229.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Raymond Building Supply Corp for free Get an email when a new federal OSHA severe-injury report for Raymond Building Supply Corp is published. One employer, no account, unsubscribe in one click.
Site address
7751 BAYSHORE RD
City
NORTH FORT MYERS
State
FL
ZIP
33917
Mailing
7751 BAYSHORE RD, NORTH FORT MYERS, FL 33917
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
300
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 13, 2014
Abate by
May 20, 2014
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a. At the establishment, employees were exposed to an amputation hazard in that, the employer did not establish a energy control program, to include but not limited to AM #3 Sn #343 009 Model 343 000E, on or about 01/08/2014
Recent events (2)
  • · I (S) $4200
  • · Z (S) $7000

1910.212 A03 II

Serious Gravity 10 2 instances 4 exposed
Issued
Mar 13, 2014
Abate by
May 20, 2014
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     a. At the establishment employees were exposed to amputation hazards, in that, guards were missing while operating the Commander 00-111-6, on or about 01/07/14     b. At the establishment employees were exposed to an amputation hazard in that, the guard was missing while operating the Kval 9100, on about 01/07/12
Recent events (2)
  • · I (S) $4200
  • · Z (S) $7000

1910.303 B07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 13, 2014
Abate by
May 20, 2014
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:    a. At the establishment, employees were exposed to an shock hazard, in that, the knock outs in a 2-Gang Square Electrical Box with live wiring was being used as a power source, on or about 01/7/2014
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.304 G05

Other-than-serious 1 instance 4 exposed
Issued
Mar 13, 2014
Abate by
May 20, 2014
Penalty
Initial $1,000 · Current $600 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   a. At the site, employees were exposed to a shock hazard, in that, the ground pin was missing on the fan cord, on or about 01/07/2014.
Recent events (2)
  • · I (O) $600
  • · Z (O) $1000

View Raymond Building Supply Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339541229.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.