OSHA Inspection: UNITED SIGNS & SIGNALS, INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of UNITED SIGNS & SIGNALS, INC in STATE RD. 50 & US HWY 19, WEEKI WACHEE, FL 34614 (NAICS 238210). OSHA activity number 339543035.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Signs & Signals, INC — free Get an email when a new federal OSHA severe-injury report for United Signs & Signals, INC is published. One employer, no account, unsubscribe in one click.
Site address
STATE RD. 50 & US HWY 19
City
WEEKI WACHEE
State
FL
ZIP
34614
Mailing
28248 C.R. 561, TAVARES, FL 32778
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.1408 A02

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 2, 2014
Abate by
Jul 25, 2014
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1926.1408(a)(2): When the employer determined that any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could come closer than 20 feet to a power line, they did not meet the requirements in Option(1), Option (2), or Option (3) of this section:  a) On or about 01/09/2014 at the job site, a 46 foot long luminaire 480 volt top mount light pole was being lifted with a Simon-Telelect truck crane to be attached to a base that was located approximately 12.5 feet horizontally from an adjacent power line, bringing the equipment, load line and load closer than 20 feet to the power line.  The employer did not meet the requirements in Option (1), Option (2), or Option (3) of this section.  The pole came loose from the crane hook and fell onto the power lines, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1926.1425 C02

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 2, 2014
Abate by
Jul 18, 2014
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1926.1425(c)(2): When employees were engaged in hooking, unhooking, or guiding the load, or in the initial connection of a load to a component or structure, hooks with self-closing latches or their equivalent were not used:  a) On or about 01/09/2014 at the job site, a 46 foot long luminaire 480 volt top mount light pole was being lifted with a Simon-Telelect truck crane using a crane hook with a broken self-closing latch.  As the pole was lowered onto the base, it slipped off of the hook and fell onto an adjacent power line, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $4410
  • — Z (S) $6300

View United Signs & Signals, INC's full OSHA safety record →