PORT NECHES, TX —
OSHA Inspection: STERLING SHIPYARD, LP
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of STERLING SHIPYARD, LP in 906 MAIN ST., PORT NECHES, TX 77651 (NAICS 336611). OSHA activity number 339544934.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STERLING SHIPYARD, LP
- Site address
- 906 MAIN ST.
- City
- PORT NECHES
- State
- TX
- ZIP
- 77651
- Mailing
- 906 MAIN ST., PORT NECHES, TX 77651
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 189
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.95 I02 II A
- Issued
- Jul 11, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $4,500 · Current $7,812
General-duty citation text
29 CFR 1910.95(i)(2)(ii)(A): The employer did not ensure that hearing protectors were worn by any employee who was exposed to an 8-hour time-weighted average of 85 decibels or greater and had not yet had a baseline audiogram established pursuant to 29 CFR 1910.95(g)(5)(ii): a) In the yard, on or about April 9, 2014, where a welder exposed to continuous noise levels in excess of the allowable 8-hour Time Weighted Average (TWA) sound level of 85 dBA was not wearing hearing protectors and had not had a baseline audiogram. Noise sampling performed for 438 minutes indicated that the welder was exposed to 92.1% of noise dose which is equivalent to approximately 89.4 dBA. Zero exposure was assumed for the 42 minutes not sampled.
Recent events (2)
- — I (S) $7812
- — Z (S) $4500
1910.95 D01
- Issued
- Jul 11, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $12,600 · Current $0 Reduced
8110
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceeded the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a) In the yard, on or about April 9, 2014, where an audiometric testing program had not been established and implemented for welders exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 424 minutes indicated that a welder was exposed to 241% of noise dose which is equivalent to approximately 96.3 dBA. Zero exposure was assumed for the 56 minutes not sampled. b) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for ship fitters exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 454 minutes indicated that a ship fitter was exposed to 158.8% of noise dose which is equivalent to approximately 93.3 dBA. Zero exposure was assumed for the 26 minutes not sampled. c) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for ship fitters exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 456 minutes indicated that a ship fitter was exposed to 116.5% of noise dose which is equivalent to approximately 91.1 dBA. Zero exposure was assumed for the 24 minutes not sampled. d) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for ship fitter helpers exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 445 minutes indicated that a ship fitter was exposed to 94.72% of noise dose which is equivalent to approximately 89.6 dBA. Zero exposure was assumed for the 35 minutes not sampled. e) In the yard, on or about April 9, 2014, where an audiometric testing program had not been established and implemented for welders exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 438 minutes indicated that a welder was exposed to 92.1% of noise dose which is equivalent to approximately 89.4 dBA. Zero exposure was assumed for the 42 minutes not sampled. f) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for forklift operators exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 436 minutes indicated that a forklift operator was exposed to 66.0% of noise dose which is equivalent to approximately 87.0 dBA. Zero exposure was assumed for the 44 minutes not sampled. Sterling Shipyard was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 908918, citation number 1, item number 2 and was affirmed as a final order on November 21, 2013, with respect to a workplace located at 906 Main Street, Port Neches, Texas 77651.
Recent events (2)
- — I (R) $0
- — Z (R) $12600
1910.95 G01
- Issued
- Jul 11, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $12,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program by making audiometric testing available to all employees whose exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels: a) In the yard, on or about April 9, 2014, where an audiometric testing program had not been established and implemented for welders exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 424 minutes indicated that a welder was exposed to 241% of noise dose which is equivalent to approximately 96.3 dBA. Zero exposure was assumed for the 56 minutes not sampled. b) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for ship fitters exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 454 minutes indicated that a ship fitter was exposed to 158.8% of noise dose which is equivalent to approximately 93.3 dBA. Zero exposure was assumed for the 26 minutes not sampled. c) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for ship fitters exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 456 minutes indicated that a ship fitter was exposed to 116.5% of noise dose which is equivalent to approximately 91.1 dBA. Zero exposure was assumed for the 24 minutes not sampled. d) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for ship fitter helpers exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 445 minutes indicated that a ship fitter was exposed to 94.72% of noise dose which is equivalent to approximately 89.6 dBA. Zero exposure was assumed for the 35 minutes not sampled. e) In the yard, on or about April 9, 2014, where an audiometric testing program had not been established and implemented for welders exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 438 minutes indicated that a welder was exposed to 92.1% of noise dose which is equivalent to approximately 89.4 dBA. Zero exposure was assumed for the 42 minutes not sampled. f) In the yard, on or about April 10, 2014, where an audiometric testing program had not been established and implemented for forklift operators exposed to continuous noise levels in excess of the allowable 8-hour time-weighted average (TWA) sound level of 85 dBA. Noise sampling performed for 436 minutes indicated that a forklift operator was exposed to 66.0% of noise dose which is equivalent to approximately 87.0 dBA. Zero exposure was assumed for the 44 minutes not sampled. Sterling Shipyard was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 908918, citation number 1, item number 1a and was affirmed as a final order on November 21, 2013, with respect to a workplace located at 906 Main Street, Port Neches, Texas 77651.
Recent events (2)
- — I (R) $0
- — Z (R) $12600
1910.134 I07
- Issued
- Jul 11, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $4,500 · Current $2,790 Reduced
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: a) at the shipyard, in the repair area, an Ingersoll Rand, model 825, serial #04-0960, oil lubricated compressor used to supply breathing air did not have a high-temperature alarm or a carbon monoxide alarm.
Recent events (2)
- — I (S) $2790
- — Z (S) $4500
1910.180 D04
- Issued
- Jul 11, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $6,300 · Current $1,116 Reduced
General-duty citation text
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(2)(ii) with a determination made as to whether deficiencies constituted a safety hazard: a) At the shipyard, frequent and periodic inspections had not been performed on an 80-ton capacity Manitowoc Crane, model number 3900, serial number 39296. b) At the shipyard, frequent and periodic inspections had not been performed on an 80-ton capacity Manitowoc Crane, model number 3900, serial number 39129. d) At the shipyard, frequent and periodic inspections had not been performed on a 150-ton capacity Link Belt Crane, model number LS 518, serial number 4EW525.
Recent events (2)
- — I (S) $1116
- — Z (S) $6300
1910.304 B03 II A
- Issued
- Jul 11, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $6,300 · Current $3,906 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that were not part of the permanent wiring of the building or structure and that were in use by personnel did not have ground-fault circuit-interrupter (GFCI) protection for personnel: a) on March 26, 2014, at the facility, a DeWalt grinder was energized by a 125-volt single-phase, 15 ampere outlet without a GFCI on an electric Miller welding machine. b) on March 26, 2014, at the facility, a Roybi grinder and a IK-12 Beetle Torch were energized by a 125-volt single-phase, 15 ampere outlet without a GFCI on an electric Miller welding machine.
Recent events (2)
- — I (S) $3906
- — Z (S) $6300
1910.305 B01 II
- Issued
- Jul 11, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $4,500 · Current $2,790 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) At the shipyard, main electrical east side plant, on the 480 volt breaker box part of the dead front was missing and unused openings for breakers had not been covered or effectively closed. b) At the shipyard, main electrical east side plant, on the 120 volt breaker box unused openings for breakers had not been covered or effectively closed.
Recent events (2)
- — I (S) $2790
- — Z (S) $4500
1915.134 C
- Issued
- Jul 11, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $3,600 · Current $2,232 Reduced
General-duty citation text
29 CFR 1915.134(c): Portable abrasive wheels used for external grinding were not protected by a guard meeting the requirements of 1915.134(e): a) In the yard, a hand-held, portable DeWalt, 120 VAC, 11,000 rpm, 4-1/2" angle grinder was not guarded.
Recent events (2)
- — I (S) $2232
- — Z (S) $3600
1910.134 I05 IV
- Issued
- Jul 11, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The tag containing the most recent change to the sorbent beds was not kept or maintained at the compressor: a) At the shipyard repair area, a tag containing the most recent change to the filter was not maintained at the compressor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sterling Shipyard, LP
View Sterling Shipyard, LP's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339544934.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.