Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: SYCAMORE HOME IMPROVEMENT, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SYCAMORE HOME IMPROVEMENT, INC. in 3432 NEWARK ST., NW, WASHINGTON, DC 20015 (NAICS 236115). OSHA activity number 339547028.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sycamore Home Improvement, INC. for free Get an email when a new federal OSHA severe-injury report for Sycamore Home Improvement, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3432 NEWARK ST., NW
City
WASHINGTON
State
DC
ZIP
20015
Mailing
4427 CHESNUT LANE, ROCKVILLE, MD 20853
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.150 A03

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 13, 2014
Abate by
Apr 2, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.150(a)(3): Firefighting equipment, provided by the employer, was not conspicuously located:   a)  Basement - On or about 01/09/201, a portable fire extinguisher was not conspicuously located, in that, the extinguisher was stored underneath a stairway and not in plain sight.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $1200

1926.153 L

Serious Gravity 1 2 instances 4 exposed
Issued
Mar 13, 2014
Abate by
Apr 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.153(l): LP-Gas storage locations were not provided with at least one approved portable fire extinguisher having a rating of not less than 20B:C:   a)  Basement - On or about 01/09/2014, a salamander type portable temporary heater connected to a 100 lbs. of compressed LP gas was not provided with a portable fire extinguisher.     b)  First Floor - On or about 01/09/2014, a salamander type portable temporary heater connected to a 100 lbs. of compressed LP gas was not provided with a portable fire extinguisher.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $0

1926.304 F

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 13, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.304(f): Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery:           a)      Front Yard - On or about 001/09//2014, employees  were exposed to amputation hazards from use a portable table saw that was missing the following requirements:             - Hood with which to protect a carpenter from accidentally contacting the saw's rotating blade while ripping wood trim, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(a).          - Spreader with which to protect carpenters wood  trim and other materials fed into the saw from binding and being ejected, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(b).          - A restart switch that would prevent the saw from unexpectedly restarting after a temporary interruption of power, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 3.1.3(c).          Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $2000

View Sycamore Home Improvement, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339547028.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.