WICHITA, KS —
OSHA Inspection: FERROLOY, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FERROLOY, INC. in 515 E. 29TH ST., WICHITA, KS 67219 (NAICS 331511). OSHA activity number 339547564.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FERROLOY, INC.
- Site address
- 515 E. 29TH ST.
- City
- WICHITA
- State
- KS
- ZIP
- 67219
- Mailing
- 515 E. 29TH ST., WICHITA, KS 67219
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 45
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.95 C01
- Issued
- Jun 27, 2014
- Abate by
- Aug 14, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average (TWA) sound level of 85 dBA: An effective hearing conservation program which included noise monitoring, audiometric testing of employees and training of employees as detailed in the standard was not instituted for the following employees: a) Two employees working in the parts grinding area were exposed to a recorded personal noise dosimeter sound level of 92 decibels during the 420 minute sampling period on 1/30/14. b) An employee working in the molding area was exposed to a recorded personal noise dosimeter sound level of 90 decibels during the 420 minute sampling period on 1/30/14.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.253 B04 III
- Issued
- Jun 27, 2014
- Abate by
- Jul 14, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Employees were exposed to fire and explosion hazards in that the oxygen and acetylene cylinders were stored together in the maintenance shop.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.1000 A02
- Issued
- Jun 27, 2014
- Abate by
- Aug 14, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.1000(a)(2): An employee was exposed to an airborne concentration of particulates not otherwise regulated (PNOR) total dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 15 milligrams per cubic meter. The following employee was exposed to inhalation hazards of PNOR total dust in that their personal exposure exceeded the OSHA Personal Exposure Limit (PEL): An employee engaged in furnace relining was exposed to PNOR total dust levels in excess of the OSHA PEL of 15 milligrams per cubic meter during the personal sampling performed on 2/08/14. The employee exposure was 24 milligrams per cubic meter, 1.5 times the PEL.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.1000 E
- Issued
- Jun 27, 2014
- Abate by
- Feb 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): An employee engaged in furnace relining was exposed to PNOR total dust levels in excess of the OSHA PEL of 15 milligrams per cubic meter during the personal sampling performed on 2/08/14. During the furnace relining job tasks administrative or engineering controls were not determined and implemented.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Ferroloy, INC.
View Ferroloy, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331511)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339547564.