Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FERROLOY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FERROLOY, INC. in 515 E. 29TH ST., WICHITA, KS 67219 (NAICS 331511). OSHA activity number 339550006.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ferroloy, INC. — free Get an email when a new federal OSHA severe-injury report for Ferroloy, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FERROLOY, INC.
Site address
515 E. 29TH ST.
City
WICHITA
State
KS
ZIP
67219
Mailing
515 E. 29TH ST., WICHITA, KS 67219
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
45
Ownership type
A

5 citations on file for this inspection.

1910.23 A08

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 27, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons could accidentally walk was not guarded by either a standard railing with standard toeboard on all exposed sides, or a floor hole cover of standard strength and construction.  While the cover was not in place, the floor hole was not constantly attended by someone or protected by a removable standard railing:  Melt deck / Pouring area - A floor hole was not guarded to protect employees from tripping hazards created by walking-by or working in front of the main control panel.  29 CFR 1910.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.147 C01

Other-than-serious 1 instance 3 exposed
Issued
Jan 27, 2014
Abate by
Apr 22, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source and rendered inoperative:    Production area - Employees performing servicing and maintenance operations were exposed to hazards associated with the unexpected energizing or start-up of the equipment such as but not limited to the 1973 Match - Blomatic Molding Machine, the 1982 Match - Blomatic Molding Machine, the Mullor Sand Distribution System, and the Inductotherm electric furnace.  Employer did not develop written program for control of potentially hazardous energy on equipment.    29 CFR 1910.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (O) $2450
  • — Z (S) $4900

1910.147 C04 II

Other-than-serious 1 instance 3 exposed
Issued
Jan 27, 2014
Abate by
Apr 22, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    Production area - Employees performing servicing and maintenance operations were exposed to hazards associated with the unexpected energizing or start-up of the equipment such as but not limited to the 1973 Match - Blomatic Molding Machine, the 1982 Match - Blomatic Molding Machine, the Mullor Sand Distribution System, and the Inductotherm electric furnace.  The written specific procedures for control of potentially hazardous energy on these equipment were inadequate in that they are just a list of energy sources and their locations, there are no step by step specific and clear instruction procedures.    29 CFR 1910.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (O) $2450
  • — Z (S) $4900

1910.212 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Jan 27, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts, flying chips:  Machine guarding was not provided for the following equipment to protect operators and other employees from laceration and possible amputation injuries hazards created by rotating parts:    a) Molding machining area - 1973 Match - Blomatic Molding Machine Serial #BSM 2016-310-7309.  No machine guarding on top and only partial guarding on the left front side of the operator position.  b) Molding machining area - 1982 Match - Blomatic Molding Machine Serial #TBM 2016-109-8201.  No machine guarding on top and only partial guarding on the left front side of the operator position.  29 CFR 1910.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 27, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Molding machining area - Point of operation was not guarded on the front side of the 1973 Match - Blomatic Molding Machine Serial #BSM 2016-310-7309 to protect operators and other employees from laceration and possible amputation injuries hazards. The two-hand tripping devices will still possibly actuate while the operator and/or the helper hands were inside the danger zone.  29 CFR 1910.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View Ferroloy, INC.'s full OSHA safety record →