Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WAUSEON MACHINE AND MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WAUSEON MACHINE AND MANUFACTURING, INC. in 995 ENTERPRISE DRIVE, WAUSEON, OH 43567 (NAICS 332710). OSHA activity number 339548208.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wauseon Machine and Manufacturing, INC. for free Get an email when a new federal OSHA severe-injury report for Wauseon Machine and Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
995 ENTERPRISE DRIVE
City
WAUSEON
State
OH
ZIP
43567
Mailing
995 ENTERPRISE DRIVE, WAUSEON, OH 43567
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 15, 2014
Abate by
Apr 24, 2014
Penalty
Initial $3,850 · Current $1,900 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Wauseon Machine and Manufacturing, Inc. - Wauseon, Ohio:  On or about January 10, 2014, employees operating the Romi Bridgeport manufactured  EZ-Path lathe (Serial #002-078690-325, Maint. #406) were exposed to injuries from the machine's rotating parts and pinch points.  An employee had bypassed the sliding cover guard and accessed the hazard area of the machine while it was in operation.  Employees were exposed to caught-on injuries from the rotating chuck while engaged in this activity.
Recent events (2)
  • · I (S) $1900
  • · Z (S) $3850

1910.332 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 15, 2014
Abate by
Oct 15, 2014
Penalty
Initial $3,850 · Current $1,925 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:    a) Wauseon Machine and Manufacturing, Inc. - Wauseon, Ohio:  On or about December 27, 2013, the employer did not ensure that employees were provided with training on electrical safety-related work practices, such as but not limited to electrical shock hazards, arc flash/blast hazards, and protective equipment for the face, head, hands and body to protect against electrical hazards while working on or near energized or potentially energized conductors.  Employees engaged in fuse changing activities along with general electrical service/repair and did not utilize electrical safety-related work practices.
Recent events (2)
  • · I (S) $1925
  • · Z (S) $3850

1910.333 A

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 15, 2014
Abate by
Jun 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:     a) Wauseon Machine and Manufacturing, Inc. - Wauseon, Ohio:  On or about December 27, 2013, the employer did not ensure that electrical safety-related work practices were utilized to prevent electrical shock or other injuries when employees were performing maintenance operations on electrical systems.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 15, 2014
Abate by
Jun 8, 2014
Penalty
Initial $3,850 · Current $1,925 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    a) Wauseon Machine and Manufacturing, Inc. - Wauseon, Ohio:  On or about December 27, 2013, the employer did not ensure that employees were protected from electrical hazards in that electrical protective equipment for the hands and body were not provided to employees who accessed potentially live electrical panels.  The employees were exposed to 480 volts while verifying power to electrical panels and while engaged in activities such as, but not limited to checking fuses and troubleshooting equipment.
Recent events (2)
  • · I (S) $1925
  • · Z (S) $3850

View Wauseon Machine and Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339548208.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.