ROUND ROCK, TX ·
OSHA Inspection: CONSOLIDATED METAL TECHNOLOGIES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONSOLIDATED METAL TECHNOLOGIES INC. in 800 N. GEORGETOWN STREET, ROUND ROCK, TX 78664 (NAICS 332813). OSHA activity number 339554073.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONSOLIDATED METAL TECHNOLOGIES INC.
- Site address
- 800 N. GEORGETOWN STREET
- City
- ROUND ROCK
- State
- TX
- ZIP
- 78664
- Mailing
- 800 N. GEORGETOWN STREET, ROUND ROCK, TX 78664
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 90
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.157 C01
- Issued
- Feb 14, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On or about 17 January 2014, and at time prior thereto, the employer did not locate portable fire extinguishers so that they were readily accessible without subjecting the employees to injuries. 1) Next to the rollup door to the parking lot in the Plating Area, a fire extinguisher sign and bracket were present but the fire extinguisher was missing. 2) Next to the internal door from the Plating Area to Line 17, north side, a fire extinguisher sign and bracket were present but the fire extinguisher was missing. 3) Next to the internal door from the Plating Area to Line 17, south side, a fire extinguisher was mounted but the sign was missing. 4) In the Cleanroom alcove where the supplies are kept, a fire extinguisher sign and bracket were present but the fire extinguisher was sitting on the floor underneath.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.178 Q01
- Issued
- Feb 14, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel. On or about 17 January 2014, and at times prior thereto, an employee was operating the Toyota 3000 Pound LPG Forklift #1 within the shipping and receiving area without the use of an operable horn, backup alarm, or backup lights, exposing the employees working or traversing in the area to hazards such as, but not limited to being struck by or crushed by the forklift.
Recent events (2)
- · I (S) $2520
- · Z (S) $4200
1910.305 B01 I
- Issued
- Feb 14, 2014
- Abate by
- Feb 21, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions. On or about 17 January 2014, and at times prior thereto, employees performing work within Lines 13, 14 and 17 of the facility were utilizing a two-plug outlet in which a conduit connector to the outlet was loose with the internal wires visible and exposed to rubbing against the knockout opening, exposing the employees to an electrical hazard of approximately 120 volts.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
1910.305 B02 I
- Issued
- Feb 14, 2014
- Abate by
- Feb 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy. On or about 17 January 2014, and at times prior thereto, employees performing work within Lines 13, 14 and 17 of the facility were utilizing a two-plug outlet in which the faceplate for the outlet was loose and hanging on a cord that was plugged in at the time with the internal wires and circuits of the outlet visible, exposing the employees to an electrical hazard of approximately 120 volts.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 J02 IV
- Issued
- Feb 14, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location. On or about 17 January 2014, and at times prior thereto, a four-plug receptacle outlet within the Lab and adjacent to the sink was being used for wholesale testing by an employee that did not have ground fault circuit interrupter (GFCI), exposing the employee to an electrical hazard of approximately 120 volts.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
More inspections at Consolidated Metal Technologies INC.
View Consolidated Metal Technologies INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339554073.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.