Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR POWDER COATING, INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUPERIOR POWDER COATING, INC in 600 PROGRESS STREET, ELIZABETH, NJ 07201 (NAICS 332812). OSHA activity number 339559023.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Powder Coating, INC — free Get an email when a new federal OSHA severe-injury report for Superior Powder Coating, INC is published. One employer, no account, unsubscribe in one click.
Site address
600 PROGRESS STREET
City
ELIZABETH
State
NJ
ZIP
07201
Mailing
600 PROGRESS STREET, ELIZABETH, NJ 07201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
115
Ownership type
A

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 5, 2014
Abate by
Jul 10, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.22(a)(1):  Places of employment were not kept clean and orderly and in a sanitary condition.             Superior Powder Coating, Inc. / NJ Site: Green line Production Area -  Combustible dust was not cleaned off of Class I Div 2 rated and electrical equipment, including but not limited to dust collection equipment, vacuum, electrical junction box, breaker, and outlet receptacles.       Observed on/or about 03/13/2014.
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.95 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 5, 2014
Abate by
Jul 30, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95( c) through (n ) was not instituted when employee noise exposures equaled or exceeded an 8 hour time weighted average sound level (TWA) of 85dBA:            Superior Powder Coating, Inc/ NJ site: The Employer did not provide a continuing effective Hearing Conservation Program for employees exposed to noise above 85 dBA. Employees were exposed to continuous noise levels equivalent to 75.54% (87.9 dbA), 90.80% (89.3dbA), and 327% (98.5dbA) respectively of the allowable dose of 50%, or 85 dBA for an 8-hour TWA. The levels are above the 8-hour TWA of 85dBA over 400 minutes. Zero exposure was assumed for all unsampled time periods.     Observed on or about 03/06/2014.
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.307 C

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 5, 2014
Abate by
Jul 10, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.307(c):  Equipment, wiring methods, and installations of equipment in hazardous Class II, Division 2 locations were not intrinsically safe, or approved for the hazardous Class Division 2 location, or safe for the hazardous Class II Division 2 location:     Superior Powder Coating, Inc /NJ Site: Green Line Production Area - Approved electrical equipment including, but not limited to electrical breaker, panel, junction and outlet receptacles (rated 480 volts/3 phase) were not provided in Class II Division 2 location where employees are exposed to combustible dust. Electrical equipment was not rated Class II  Division 2 and/or moved 25 feet away from the Class II Division 2 location.     Observed on/or about 05/02/2014.      Reference:    Site Safety Data Sheets: Brite Bond Stardust Silver II (Powder Coat)    NFPA 499 Classification of Combustible Dusts and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas 2008 Edition  Chapter 5 Section 5.3      NFPA 654 Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids 2006 Edition  Chapter 6 Section 6.6      NFPA 70E Standard for Electrical Safety in the Workplace - Article 440.4 29 CFR 1910.307 General
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Jun 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Where the employer provided respirators for employees to use voluntarily, the employer  did not provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"):        Superior Powder Coating, Inc/ NJ site - Production floor: Employee(s) were not provided with Appendix D when N95 NIOSH approved filtering face piece respirators  were voluntarily worn by employees during production operations.   Observed on or about 01/10/14.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Superior Powder Coating, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339559023.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.