NEW BERLIN, WI —
OSHA Inspection: ACS GROUP, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ACS GROUP, INC. in 2900 S. 160TH STREET, NEW BERLIN, WI 53151 (NAICS 334513). OSHA activity number 339559312.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACS GROUP, INC.
- Site address
- 2900 S. 160TH STREET
- City
- NEW BERLIN
- State
- WI
- ZIP
- 53151
- Mailing
- 2900 S. 160TH STREET, NEW BERLIN, WI 53151
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334513
- Employees
- 258
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.132 A
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $5,610 · Current $3,927 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) In the gas filling room the employee was not required to wear coveralls that protected him from the hazard of a flash fire while handling and transferring flammable compressed gases such as methyl chloride, ethyl chloride, propane, butane and isobutane.
Recent events (2)
- — I (S) $3927
- — Z (S) $5610
1910.133 A01
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $5,610 · Current $3,927 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: (a) In the gas filling room employees were not required to wear a face shield to protect the face from splashes of chemicals such as methylene chloride when transferring the chemicals from original containers into a bottle for mixing and then pouring that mix into the gas filling panel.
Recent events (2)
- — I (S) $3927
- — Z (S) $5610
1910.1052 I02
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1052(i)(2): It was reasonably foreseeable that an employee's eyes may contact solutions containing 0.1 percent or greater methylene chloride and the employer did not provide appropriate eyewash facilities within the immediate work area for emergency use and did not ensure that affected employees use those facilities when necessary: (a) The employee in the gas filling room handled methylene chloride and there was no adequate eye wash facility available for immediate emergency use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $2,805 · Current $1,964 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) The employee in the gas filling room was wearing the negative pressure half-face piece respirator and the supplied air respirator and had not been given a medical evaluation.
Recent events (2)
- — I (S) $1963.5
- — Z (S) $2805
1910.134 H02 I
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $2,805 · Current $1,964 Reduced
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) In the gas filling room the 3M half face-piece elastomeric air purifying respirator fitted with organic cartridges and particle prefilters was left sitting on the top of a gas cylinder.
Recent events (2)
- — I (S) $1963.5
- — Z (S) $2805
1910.138 A
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $5,610 · Current $3,927 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: (a) In the gas filling room the employee did not wear gloves when opening a valve on the gas filling apparatus to vent ethyl chloride gas which then impinged upon his hand when vented.
Recent events (2)
- — I (S) $3927
- — Z (S) $5610
1910.303 B02
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $3,740 · Current $2,618 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) At the gas filling room the Tripplite surge suppressor with a label indicating a maximum load of 15 amps had the vacuum pump, the breathing air pump and the buffer connected with a total connected load of 23.2 amps.
Recent events (2)
- — I (S) $2618
- — Z (S) $3740
1910.307 C
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $5,610 · Current $3,927 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) In the gas filling room the fan used to exhaust flammable vapors was not rated Class I, Division 1.
Recent events (2)
- — I (S) $3927
- — Z (S) $5610
1910.1052 D01 I
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $5,610 · Current $3,927 Reduced
General-duty citation text
29 CFR 1910.1052(d)(1)(i): Where methylene chloride was present in the workplace, the employer did not determine each employee's exposure: (a) Methylene chloride was used in the gas filling room and no determination was done by either personal breathing zone air sampling of each employee or by personal breathing zone air sampling that was representative of each employee.
Recent events (2)
- — I (S) $3927
- — Z (S) $5610
1910.1052 L03 I
- Issued
- May 13, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1052(l)(3)(i): The employer did not inform each affected employee of the requirements of 29 CFR 1910.1052 and the information available in its appendices and/or how to access or obtain a copy of it in the workplace: (a) Methylene chloride was used in the gas filling room and there had been no determination done, either by personal breathing zone air sampling of each employee in the gas filling room or by personal breathing zone air sampling that was representative of each employee.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ACS Group, INC.
View ACS Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339559312.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.