PHENIX CITY, AL —
OSHA Inspection: INDUSTRIAL INSULATION GROUP, LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of INDUSTRIAL INSULATION GROUP, LLC in 908 JOHN BUSSEY DRIVE, PHENIX CITY, AL 36869 (NAICS 238310). OSHA activity number 339570764.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL INSULATION GROUP, LLC
- Site address
- 908 JOHN BUSSEY DRIVE
- City
- PHENIX CITY
- State
- AL
- ZIP
- 36869
- Mailing
- 908 JOHN BUSSEY DRIVE, PHENIX CITY, AL 36869
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.219 D01
- Issued
- Jun 17, 2014
- Penalty
- Initial $5,500 · Current $5,500
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Joe Roll-up: On or about January 9, 2014 and at times prior thereto, the employer did not ensure machine guarding was installed and/or in place during use which exposed an employee to amputations and other injuries associated with being caught-in the nip points of the belt and pulley system.
Recent events (1)
- — Z (S) $5500
1910.219 E01 I
- Issued
- Jun 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a) Joe Roll-up: On or about January 9, 2014 and at times prior thereto, the employer did not ensure machine guarding was installed and/or in place during use which exposed an employee to amputations and other injuries associated with being caught-in the nip points of the belt and pulley system.
Recent events (1)
- — Z (S) $0
More inspections at Industrial Insulation Group, LLC