OSHA Inspection: DELL MARINE, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DELL MARINE, LLC in 13911 ATLANTIC BOULEVARD, JACKSONVILLE, FL 32225 (NAICS 488330). OSHA activity number 339577371.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dell Marine, LLC for free Get an email when a new federal OSHA severe-injury report for Dell Marine, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DELL MARINE, LLC
Site address
13911 ATLANTIC BOULEVARD
City
JACKSONVILLE
State
FL
ZIP
32225
Mailing
5137 ARLINGTON ROAD, JACKSONVILLE, FL 32247
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488330
Employees
10
Ownership type
Private (A)

8 citations on file for this inspection.

1910.101 B

Serious Gravity 10 1 instance 8 exposed
Issued
Apr 18, 2014
Abate by
Jun 5, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   a. On or about February 4, 2014, at the main bay door to the fabrication shop, 31 oxygen compressed gas cylinders were not immobilized by chains or other means to prevent them from being knocked over, exposing employees to potential struck-by, explosion, fire, and burn hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.253 B04 III

Serious Gravity 10 1 instance 8 exposed
Issued
Apr 18, 2014
Abate by
Jun 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a. On or about February 4, 2014, at the main bay door to the fabrication shop, 31 oxygen compressed gas cylinders were not separated from 45 fuel compressed gas cylinders, exposing employees to potential explosion, fire and burn hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.180 D03

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 18, 2014
Abate by
Jun 5, 2014
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.180(d)(3): 29 CFR 1910.180(d)(3): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(i) with a determination made as to whether deficiencies constituted a safety hazard:  a. On or about January 6, 2014, the America brand, 7670 model, mobile wagon crane was not was not inspected frequently at intervals no greater than 1 month for defects of items including but not limited to; All control mechanisms for maladjustment, excessive wear and contamination by lubricants or other foreign materials, all safety devices, deterioration or leakage of air or hydraulic systems and hooks, exposing employees to falling object, struck-by and crushing hazards.   b. On or about January 30, 2014, the America brand, 7670 model, mobile wagon crane was not was not inspected frequently at intervals no greater than 1 month for defects of items including but not limited to; All control mechanisms for maladjustment, excessive wear and contamination by lubricants or other foreign materials, all safety devices, deterioration or leakage of air or hydraulic systems and hooks, exposing employees to falling object, struck-by and crushing hazards.   c. On or about January 30, 2014, the Lorain brand, LCD110 model, fixed cab mobile crane was not was not inspected frequently at intervals no greater than 1 month for defects of items including but not limited to; All control mechanisms for maladjustment, excessive wear and contamination by lubricants or other foreign materials, all safety devices, deterioration or leakage of air or hydraulic systems and hooks, exposing employees to falling object, struck-by and crushing hazards.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.180 D04

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 18, 2014
Abate by
Jun 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(ii) with a determination made as to whether deficiencies constituted a safety hazard:   a. On or about February 4, 2014, a complete periodic inspection of the of the America brand, 7670 model, mobile wagon crane was not conducted within the past 12 months to identify defects, exposing employees to falling object, struck-by and crushing hazards.   b. On or about February 4, 2014, a complete periodic inspection of the of the Lorain brand, LCD110 model, fixed cab mobile crane was not conducted within the past 12 months to identify defects, exposing employees to falling object, struck-by and crushing hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2014
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a. On or about January 4, 2014, in the fabrication shop, an employee used the Marvel brand band saw where the unused portions of the saw blade located directly above and below the point of operation of the blade was not guarded, exposing the employee to point of operation, flying debris and amputation hazards.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.219 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv):   a. On or about January 4, 2014, in the fabrication shop, an employee used the Marvel brand band saw to cut metal bars while the saw blade upper and lower flywheels were not enclosed or guarded, exposing the employee to struck-by and caught-in hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  a. On or about January 4, 2014, in the fabrication shop, an employee used the Marvel brand band saw to cut metal bars while a horizontal power take off shaft was not guarded, exposing employee to caught-in and amputation hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   a. On or about January 4, 2014, in the fabrication shop, an employee used the Marvel brand band saw to cut metal bars while the power-transmission upper and lower pulleys were not guarded, exposing employee to caught-in and amputation hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Dell Marine, LLC's full OSHA safety record →