Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: NOAA PACIFIC MARINE ENVIRONMENTAL LABORATORY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NOAA PACIFIC MARINE ENVIRONMENTAL LABORATORY in 7600 SAND POINT WAY NE BUILDING 3, BUILDING 8, HANGAR 32, SEATTLE, WA 98115 (NAICS 541710). OSHA activity number 339581738.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Noaa Pacific Marine Environmental Laboratory — free Get an email when a new federal OSHA severe-injury report for Noaa Pacific Marine Environmental Laboratory is published. One employer, no account, unsubscribe in one click.
Site address
7600 SAND POINT WAY NE BUILDING 3, BUILDING 8, HANGAR 32
City
SEATTLE
State
WA
ZIP
98115
Mailing
7600 SAND POINT WAY NE, SEATTLE, WA 98115
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541710
Employees
81
Ownership type
D

7 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees' ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a)       Building 8, Welding Shop;  A North 7190N99 elastomeric respirator was available for employee use and the employee who used the respirator had not undergone a medical evaluation.
Recent events (1)
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  a)       Building 8, Welding Shop;  A North 7190N99 elastomeric respirator was stored unprotected on a workbench.
Recent events (1)
  • — Z (S) $0

1910.145 C02 I

Serious Gravity 5 5 instances 10 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:   a) Building 8, Room 121, OCS Lab; The employer did not post caution signs to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder.   b)  Building 3, Room 1107, Electronics Lab; The employer did not post caution signs to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder.  c) Building 3, Room 1105; The employer did not post caution signs to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder.  d) Building 3, Room 1082;  The employer did not post caution signs to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder.  e) Building 3, Room 1023; The employer did not post caution signs to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder.
Recent events (1)
  • — Z (S) $0

1910.1025 H01

Serious Gravity 5 4 instances 8 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:   a)      Building 3, Room 1107, Electronics Lab; The work bench where soldering was performed was contaminated with lead and a housekeeping schedule was not in place to ensure all surfaces were maintained as free as practicable of accumulations of lead.   b)      Building 3, Room 1105; The work bench where soldering was performed was contaminated with lead and a housekeeping schedule was not in place to ensure all surfaces were maintained as free as practicable of accumulations of lead.   c)       Building 3, Room 1082; The work bench where soldering was performed was contaminated with lead and a housekeeping schedule was not in place to ensure all surfaces were maintained as free as practicable of accumulations of lead.   d)      Building 3, Room 1023; The work bench where soldering was performed was contaminated with lead and a housekeeping schedule was not in place to ensure all surfaces were maintained as free as practicable of accumulations of lead.
Recent events (1)
  • — Z (S) $0

1910.1200 F05 I

Repeat 5 instances 10 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  a)  Building 3, Room 2105C;  A white spray bottle was not labeled. b)  Building 8, Tool Crib;  A white solvent bottle, yellow and blue spray bottle, and blue substance in a clear bottle was not labeled.  c)  Building 8, Room 121, OCS Lab;  A bottle of flux was not labeled.  d)  Building 3, Room 1107, Electronics Lab;  A bottle of flux and white bottle with unknown substance were not labeled.  e)  Building 3, Room 1105, A white/ clear spray bottle located near the soldering station was not labeled.     The National Oceanic and Atmospheric Administration was previously cited for a violation of this standard which was contained in OSHA inspection no. 309097293 citation 2, item 1A, issued on April 27, 2014 with respect to a workplace at Seattle, Washington.
Recent events (1)
  • — Z (R) $0

1910.1200 F05 II

Repeat 5 instances 10 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  a)  Building 3, Room 2105C;  A white spray bottle was not marked with hazard warnings.  b)  Building 8, Tool Crib;  A white solvent bottle, yellow and blue spray bottle, and blue substance in a clear bottle was not  marked with hazard warnings. c)  Building 8, Room 121, OCS Lab;  A bottle of flux was not marked with hazard warnings. d)  Building 3, Room 1107, Electronics Lab;  A bottle of flux and white bottle with unknown substance were not marked with hazard warnings. e)  Building 3, Room 1105, A white/ clear spray bottle located near the soldering station was not marked with hazard warnings.  The National Oceanic and Atmospheric Administration was previously cited for a violation of this standard which was contained in OSHA inspection no. 309097293 citation 2, item 1B, issued on April 27, 2014 with respect to a workplace at Seattle, Washington.
Recent events (1)
  • — Z (R) $0

1910.134 C02 I

Other-than-serious 3 instances 15 exposed
Issued
Apr 2, 2014
Abate by
May 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:   a)                    Building 8, Welding Shop; Employees voluntarily used a North 7190N99 elastomeric respirator, and they were not given a copy of the information in Appendix D by the employer.  b)                   Building 8, Potting Shop, PMEL Machine Shop;  Employees voluntarily used a 3M 8576 NIOSH P95 dust mask respirator, and they were not given a copy of the information in Appendix D by the employer.   c)                    Building 32, Machine Shop; Employees voluntarily used a AO Safety N9504C N95 dust mask respirator, and they were not given a copy of the information in Appendix D by the employer.
Recent events (1)
  • — Z (O) $0

View Noaa Pacific Marine Environmental Laboratory's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339581738.