Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: WILSON MANIFOLDS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILSON MANIFOLDS INC. in 4700 NE 11TH AVE., OAKLAND PARK, FL 33334 (NAICS 336399). OSHA activity number 339581860.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wilson Manifolds INC. for free Get an email when a new federal OSHA severe-injury report for Wilson Manifolds INC. is published. One employer, no account, unsubscribe in one click.
Site address
4700 NE 11TH AVE.
City
OAKLAND PARK
State
FL
ZIP
33334
Mailing
4700 NE 11TH AVE., OAKLAND PARK, FL 33334
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
11
Ownership type
A

11 citations on file for this inspection.

1910.136 A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 18, 2014
Penalty
Initial $1,600 · Current $880 Reduced
29 CFR 1910.136(a): The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards:    a.  On or about February 10, 2014, at the warehouse area of the above addressed jobsite, an employee who handled merchandise with weights varying in between 16.2 lbs to 67.0 lbs was not provided with steel toe footwear, exposing the employee to the risk of receiving foot injuries.
Recent events (2)
  • · I (S) $880
  • · Z (S) $1600

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 23, 2014
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a.  On or about December 10, 2013, at the hot shop area, of the above addressed jobsite, the employer failed to establish an energy control program for the control of multiple energy sources as applicable for an authorized employee to rebuild hydraulic cylinders of a HYD-MECH H-14 bandsaw, which exposed the employee to a caught by hazard.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2000

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2014
Penalty
Initial $1,200 · Current $660 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a.   On or about January 27, 2014, at the CNC department of the above addressed jobsite, an employee was exposed to a struck by hazard while working with a drill press (i.e. Accura Machine Co., Model No, SC-30, Serial No. 037911) that was not anchored.
Recent events (2)
  • · I (S) $660
  • · Z (S) $1200

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 10, 2014
Penalty
Initial $1,200 · Current $660 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     a.  On or about February 10, 2014, at the nitrous assembly area of the above addressed worksite, an employee was exposed to a struck by hazard while using compressed air for cleaning purposes at 60 psi.
Recent events (2)
  • · I (S) $660
  • · Z (S) $1200

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 10, 2014
Penalty
Initial $1,600 · Current $880 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a.  On or about February 10, 2014, at the nitrous assembly area of the above jobsite, a hot air gun (i.e. Model #750) lacked a ground prong on its attachment plug, exposing employees to an electrical hazard.
Recent events (2)
  • · I (S) $880
  • · Z (S) $1600

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,600 · Current $880 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    a.  On or about December 10, 2014, at the CNC department of the above jobsite, a welding machine lacked strain relief where its electrical cord entered into the attachment plug, exposing employees to an electrical hazard.
Recent events (2)
  • · I (S) $880
  • · Z (S) $1600

1910.212 A01

Repeat Gravity 5 4 instances 2 exposed
Issued
Apr 4, 2014
Abate by
Jun 16, 2014
Penalty
Initial $4,000 · Current $2,200 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a.   On or about February 10, 2014, at the machine room of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a milling machine (i.e. Lac-un Republic, Model FTV-2) that lacked a guard.     b.   On or about February 10, 2014, at the machine room of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a milling machine (i.e. Lac-un Republic, Model FTV-2) that lacked a guard.    c.   On or about February 3, 2014, at the CNC department of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a milling machine (i.e. Lac-un Republic, Model FTV-2) that lacked a guard.    d.   On or about January 20, 2014, at the CNC department of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a drill press (i.e. Accura Machine Co., Model No, SC-30, Serial No. 037911) that lacked a guard.      Wilson Manifolds Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 315358358, citation number 1, item number 1 and was affirmed as a final order on December 12, 2011, with respect to a workplace located at 4700 NE 11th Avenue, Oakland Park, FL 33334.
Recent events (2)
  • · I (R) $2200
  • · Z (R) $4000

1904.32 A04

Other-than-serious 1 instance 11 exposed
Issued
Apr 4, 2014
Abate by
Apr 10, 2014
Penalty
Initial $400 · Current $200 Reduced
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30:      a.  On or about February 10, 2014 at the above addressed jobsite, the employer failed to post an OSHA-300A for year 2013.
Recent events (2)
  • · I (O) $200
  • · Z (O) $400

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Apr 4, 2014
Abate by
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   a. On or about February 10, 2014, at the above referenced jobsite, the employer had not developed and implemented a hazard communication program for protecting employees from the hazards of chemicals (i.e. argon, helium, nitrogen, WD-40 lubricant, etc.) that they work with on a daily basis.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 2 exposed
Issued
Apr 4, 2014
Abate by
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s):  a. On or about February 10, 2014, at the above referenced jobsite, the safety data sheets  (i.e. argon, helium, nitrogen, WD-40 lubricant, etc.) for chemicals used by employees on a daily basis were not accessible.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Apr 4, 2014
Abate by
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a. On or about February 10, 2014, at the above referenced jobsite, the employer had not provided information and training as required to employees that worked with hazardous chemicals (i.e. argon, helium, nitrogen, WD-40 lubricant, etc.) on a daily basis, as evidenced by, among other conditions; employees lacked knowledge of the details and availability of the company's hazard communication program; employees lacked knowledge of availability of the required safety data sheets, etc.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Wilson Manifolds INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339581860.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.