EASTHAMPTON, MA ·
OSHA Inspection: ADHESIVE APPLICATIONS INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ADHESIVE APPLICATIONS INC. in 41 O'NEILL STREET, EASTHAMPTON, MA 01027 (NAICS 322222). OSHA activity number 339586562.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADHESIVE APPLICATIONS INC.
- Site address
- 41 O'NEILL STREET
- City
- EASTHAMPTON
- State
- MA
- ZIP
- 01027
- Mailing
- 41 O'NEILL STREET, EASTHAMPTON, MA 01027
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322222
- Employees
- 33
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 4, 2014
- Penalty
- Initial $8,400 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: In the coating head enclosure of coater #2: On or about February 6, 2014, an employee cleaning a rubber roller in the coating head enclosure portion of coater #2 caught his left arm in an in-going nip point between a rubber roller and a feed roller which was not protected by one or more methods of machine guarding. Adhesive Applications, Inc. was previously cited for a violation of the same standard which was contained in OSHA inspection 315515684, citation number 1, item number 1, and was affirmed as a final order on February 1, 2012, with respect to a workplace at 218 Race Street, Holyoke, MA.
Recent events (2)
- · I (R) $4200
- · Z (R) $8400
1910.106 D05 VI B
- Issued
- Jun 27, 2014
- Abate by
- Aug 14, 2014
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.106(d)(5)(vi)(b): The storage arrangement of flammable liquids in a storage building was not in accordance with Table H-14: In the flammable storage and adhesive mixing room: On or about May 1, 2014, employees working in the adhesive mixing room where 55 gallon drums of flammable liquids were stored in rows which were not separated by at least 4 feet.
Recent events (2)
- · I (S) $2100
- · Z (S) $2100
1910.106 D07 IV
- Issued
- Jun 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(7)(iv): Materials which will react with water were stored in the same room with flammable liquids: In the flammable storage and adhesive mixing room: On or about May 1, 2014: An employee was working where a water reactive material, para toluene sulfonic acid, was stored in the same room with flammable liquids.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 E02 IV D
- Issued
- Jun 27, 2014
- Abate by
- Aug 14, 2014
- Penalty
- Initial $2,625 · Current $2,625
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: In the flammable liquid storage and adhesive mixing room: On or about May 1, 2014, an employee filled a metal, open-top 5 gallon container with toluene, a category 2 flammable liquid, and then transferred the flammable liquid from the metal, open top 5 gallon container into a 55 gallon drum. The 5 gallon container was not a safety can and did not have an approved self-closing device nor was the process performed through a closed piping system.
Recent events (2)
- · I (S) $2625
- · Z (S) $2625
1910.106 E06 II
- Issued
- Jun 27, 2014
- Abate by
- Aug 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): A category 2 flammable liquid was dispensed into containers without the nozzle and container being electrically interconnected: (a) In the flammable liquid storage and solvent/adhesive mixing room: On or about May 1, 2014, an employee dispensed a category 2 flammable liquid, toluene, from a metal, 55 gallon drum, which was grounded, into a metal, open-top 5 gallon container without bonding the 5 gallon container to the 55 gallon drum. (b) In the flammable liquid storage and solvent/adhesive mixing room: On or about May 1, 2014, an employee dispensed a category 2 flammable liquid, toluene, from a metal, 5 gallon open-top container to a grounded, metal 55 gallon drum of a flammable adhesive mix without bonding the 5 gallon container to the 55 gallon drum.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B02
- Issued
- Jun 27, 2014
- Penalty
- Initial $2,100 · Current $2,100
8870
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: Near the finished end of coater #1: On or about May 1, 2014, employees working near a cable tray fitting with a missing side cover were exposed to energized electrical wiring.
Recent events (2)
- · I (S) $2100
- · Z (S) $2100
1910.305 G01 IV A
- Issued
- Jun 27, 2014
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Near the coating head enclosure of Coater #2: On or about May 1, 2014, a flexible extension cord was used in lieu of permanent wiring to provide power to a ventilation booster unit for the coating head enclosure.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Jun 27, 2014
- Abate by
- Jul 24, 2014
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.1200(h)(1): Employees was not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment: In the coating area: On or about Feb 6, 2014, a new employee working as a coating operator using methyl ethyl ketone was not provided information and training on hazardous chemicals at the time of initial assignment.
Recent events (2)
- · I (S) $2100
- · Z (S) $2100
More inspections at Adhesive Applications INC.
View Adhesive Applications INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322222)
More inspections in MA
Source