Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ECOLAB INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ECOLAB INC. in 3001 CHANNAHON RD., JOLIET, IL 60435 (NAICS 325611). OSHA activity number 339587594.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ecolab INC. for free Get an email when a new federal OSHA severe-injury report for Ecolab INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ECOLAB INC.
Site address
3001 CHANNAHON RD.
City
JOLIET
State
IL
ZIP
60435
Mailing
3001 CHANNAHON RD., JOLIET, IL 60436
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325611
Employees
340
Ownership type
Private (A)

4 citations on file for this inspection.

1910.23 A03

Serious 2 instances 3 exposed
Issued
Mar 14, 2014
Abate by
Apr 30, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.23(a)(3): Every hatchway and chute floor opening was not guarded:       a) During the period of approximately September 18, 2013 and February 18, 2014, at the above located workplace, employees were required work on one or both of the work platforms located just west and above silo 23. Both work platforms had unguarded floor openings that measured approximately 2.5 feet by 6 feet.  The employees were thereby exposed to a fall hazard of over 20 feet.          Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $7000
  • · Z (S) $7000

1910.23 A08

Other-than-serious 2 instances 3 exposed
Issued
Mar 14, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded by either a standard railing or floor hole cover:             a) On or about February 18, 2014, at the above located workplace, employees were required to work around a floor hole on the work platform at the upper level and just west of silo 23. The floor hole measured approximately 6 inches by 6 inches. Employees were thereby exposed to trips and falls hazards.            b) On or about February 18, 2014, at the above located workplace, employees were required to work around a broken floor drain cover/hole on the work platform at the midlevel and just west of silo 23. The floor hole measuring approximately 3.5 by 5 inches. Employees were thereby exposed to trips and falls hazards.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Mar 14, 2014
Abate by
Mar 20, 2014
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:             a) During the period of September 18, 2013 to February 18, 2014, employees at the above located workplace were required to work with and around a 120-220 volt screw conveyor. The screw conveyor had a "LB" (90 degree wire pulling elbow) which did not have a cover. The condition of the elbow (uncovered with exposed wires) was not in accordance with instructions included in the listing or labeling. Employees that worked at or around the floor screw conveyor were thereby exposed to an electrical hazard.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4000

1910.303 G02 I

Other-than-serious 1 instance 3 exposed
Issued
Mar 14, 2014
Abate by
Mar 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i):  Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:     a) During the period of September 18, 2013 to February 18, 2014, employees at the above located workplace were required to work with and around a 120-220 volt screw conveyor. The screw conveyor had a "LB" (90 degree wire pulling elbow) which did not have a cover. The wires in the elbow were exposed and energized. Employees that worked at or around the floor screw conveyor were thereby exposed to an electrical hazard.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

View Ecolab INC.'s full OSHA safety record →