Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: BELL BURIAL VAULT COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BELL BURIAL VAULT COMPANY in 804 BELLE AVENUE, HAMILTON, OH 45015 (NAICS 327390). OSHA activity number 339591539.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bell Burial Vault Company for free Get an email when a new federal OSHA severe-injury report for Bell Burial Vault Company is published. One employer, no account, unsubscribe in one click.
Site address
804 BELLE AVENUE
City
HAMILTON
State
OH
ZIP
45015
Mailing
804 BELLE AVENUE, HAMILTON, OH 45015
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
6
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
May 9, 2014
Penalty
Initial $1,600 · Current $800 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.    Laborer employees were exposed to a struck-by hazard on a daily basis while using a Budgit two ton underhung overhead hoist in the shop area to lift concrete burial lids and vaults weighing 800 lbs. and 1600 lbs. with the safety latch on the hook missing.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.178 L01 II

Serious Gravity 5 1 instance 5 exposed
Issued
May 9, 2014
Abate by
Jun 30, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).    The Company had not ensured that employees authorized to operate the sit-down propane forklift in the shop area had not been evaluated based upon their previous operating experience and training completed required by paragraph (l).
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.184 E04

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2014
Abate by
Jul 15, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.184(e)(4): Proof testing. The employer shall ensure that before use, each new, repaired, or reconditioned alloy steel chain sling, including all welded components in the sling assembly, shall be proof tested by the sling manufacturer or equivalent entity, in accordance with paragraph 5.2 of the American Society of Testing and Materials Specification A391-65, which is incorporated by reference as specified in Sec. 1910.6 (ANSI G61.1-1968). The employer shall retain a certificate of the proof test and shall make it available for examination.    Four leg Alloy steel chain slings used in the shop area by employees in conjunction with an overhead hoist, were constructed from components and a welded ring had not been proof tested and a certificate of the proof test was not available for examination.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
May 9, 2014
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.    In the shop area, two, 2 ft. x 2 ft. plastic box fans designed for indoor use were being used in the dusty shop environment to blow concrete dust away from the mixing area.
Recent events (2)
  • · I (O) $500
  • · Z (S) $1200

1910.37 B02

Other-than-serious 1 instance 5 exposed
Issued
May 9, 2014
Abate by
May 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."  In the Shop Area an exit door leading to the outside of the building was not marked with a sign reading Exit.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Bell Burial Vault Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339591539.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.