OSHA Inspection: PEERLESS MFG CO

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PEERLESS MFG CO in 401 US HIGHWAY 281, WICHITA FALLS, TX 76310 (NAICS 333999). OSHA activity number 339595720.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peerless MFG CO — free Get an email when a new federal OSHA severe-injury report for Peerless MFG CO is published. One employer, no account, unsubscribe in one click.
Establishment
PEERLESS MFG CO
Site address
401 US HIGHWAY 281
City
WICHITA FALLS
State
TX
ZIP
76310
Mailing
401 US HIGHWAY 281, WICHITA FALLS, TX 76310
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
85
Ownership type
A

3 citations on file for this inspection.

1910.94 C03 III A

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 18, 2014
Abate by
Jul 17, 2014
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.94(c)(3)(iii)(a): Overspray filters were not installed and maintained in accordance with the requirements of � 1910.107(b)(5), and shall only be in a   location easily accessible for inspection, cleaning, or replacement:  This violation occurred on February 21, 2014, in the spray area of the manufacturing facility, the ventilation system in the spray booth were missing filters exposing employees to breathing hazards.
Recent events (1)
  • — Z (S) $3000

1910.134 H01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 18, 2014
Abate by
Jul 17, 2014
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition:    This violation occurred on February 21, 2014, in the spray area of the manufacturing facility, the 3M full face and MSA respirators being used by employees were not maintained in a sanitary condition.
Recent events (1)
  • — Z (S) $3000

1910.179 L03 III D

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 18, 2014
Abate by
Jul 17, 2014
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean nor were function labels kept legible:    This violation occurred on February 21, 2014, and at times prior thereto, in the finishing and testing area, the pendant controls to the Kranco Houston 20-ton overhead crane was not kept clean and legible, exposing employees to being struck by suspended loads.
Recent events (1)
  • — Z (S) $4000

View Peerless MFG CO's full OSHA safety record →