SARASOTA, FL ·
OSHA Inspection: FLORIKAN ESA, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLORIKAN ESA, LLC in 1579 BARBER RD, SARASOTA, FL 34240 (NAICS 325314). OSHA activity number 339605248.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLORIKAN ESA, LLC
- Site address
- 1579 BARBER RD
- City
- SARASOTA
- State
- FL
- ZIP
- 34240
- Mailing
- 1579 BARBER RD, SARASOTA, FL 34240
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325314
- Employees
- 68
- Ownership type
- A
Citations
23 citations on file for this inspection.
1910.23 C01
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a. At the preheater material discharge, employees were exposed to a fall hazard of 4 feet 8 inches, in that, a catwalk was not provided with standard railings at the material side. b. Bagging area weigh hopper, employees were exposed to a fall hazard of 7 feet 3 inches, in that, the material handling side of the hopper catwalk was not provided with standard railings and no other fall protection is used to prevent employees from falling to the ground below.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.23 D01 III
- Issued
- Aug 22, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: a. Preheater material discharge catwalk, employees were exposed to a fall hazard, in that, a 7 step stairway 36 inches wide providing access to the catwalk was not provided with a standard railing on the left side descending. b. Weight hopper catwalk, employees were exposed to a fall hazard, in that, a 6 step stairway 36 inches wide providing access to the catwalk over the hopper was not provided with a midrail.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.24 E
- Issued
- Aug 22, 2014
- Abate by
- Nov 3, 2014
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.24(e): The fixed stairs were not installed at angles to the horizontal between 30 and 50 degrees as outlined, but not limited to the combinations given in Table D-1: a. Coating drum number 3, employees were exposed to a fall hazard, in that, the stairway used to access the catwalk was at a 66 degree angle. b. Coating drum number 1, employees were exposed to a fall hazard, in that, the stairway used to access the catwalk was at a 75 degree angle. c. At the tote rack, employees were exposed to a fall hazard, in that, the stairway used to access the catwalk at the precursor chemical rack was at a 74 degree angle.
Recent events (2)
- · I (S) $2520
- · Z (S) $4200
1910.146 C02
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a. Coating area, employees were exposed to an oxygen deficient atmosphere, heat, and mechanical hazards, in that, permit required confined spaces such as, but not limited to, the heater, the Doyle mixers and continental mixer number 3, did not have signs posted to warn employees of the hazards.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
1910.146 C04
- Issued
- Aug 22, 2014
- Abate by
- Oct 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a. Coating area, employees were exposed to an oxygen deficient atmosphere, heat, and mechanical hazards, in that, a permit required confined space program was not developed for entering permit required spaces such as, but not limited to, the heater, the Continental mixers and the Doyle mixers.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.151 C
- Issued
- Aug 22, 2014
- Abate by
- Oct 6, 2014
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a. Research and development area, during chemical mixing and chemical reactions, employees were exposed to injurious material, in that, an eye wash station and body shower were not provided for quick drenching or flushing of the eyes and body. b. Main manufacturing area battery changing station, an eye wash station and body shower were not provided for quick drenching or flushing of the eyes and body. c. Warehouse area battery charging station, an eye wash station and body shower were not provided for quick drenching or flushing of the eyes and body.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.178 G11
- Issued
- Aug 22, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.178(g)(11): Precautions were not taken to prevent open flames, sparks, or electric arcs in battery charging area(s) a. Manufacturing area at the battery charging station, employees were exposed to a fire hazard, in that, the leads of the battery charger had a frayed outer sheath in two locations with exposed conductors.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.178 L01 I
- Issued
- Aug 22, 2014
- Abate by
- Oct 17, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. At the warehouse and at the coating manufacturing areas, employees were exposed to a struck by hazard when operating forklifts without being provided the training and education required.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
1910.178 L02 III
- Issued
- Aug 22, 2014
- Abate by
- Oct 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(iii): All operator training and evaluation was not conducted by persons who had the knowledge, training, and experience to train powered industrial truck operators and evaluate their competence: a. At the warehouse and at the coating manufacturing areas, employees were exposed to a struck by hazard when operating forklifts, in that, training and education was not conducted by a person who had the knowledge, training, and experience to train powered industrial truck operators and evaluate their competence.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 P01
- Issued
- Aug 22, 2014
- Abate by
- Sep 11, 2014
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a. At the manufacturing area, employees were exposed to a struck by hazard when operating forklifts which were in need of repair, in that, forklift FL-14 did not have a horn, the right headlight did not work and the back-up alarm was inoperable. b. At the warehouse area, employees were exposed to a struck by hazard when operating forklifts which were in need of repair, in that, forklift number 16229 did not have a left headlight and did not have a rear light.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.178 Q07
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: a. Coating and bagging area and warehousing area, employees were exposed to a struck by hazard, in that, forklifts were not inspected before being placed in service to assure that the lifts were in good working condition.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Aug 22, 2014
- Abate by
- Nov 3, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Dust collector area baghouse rotary air lock, employees were exposed to a caught in hazard, in that, a guard was not installed at the bottom of the dust exhaust piping to protect employees from the moving parts. On or about 02/24/2014 an employee suffered a finger amputation from this equipment. b. Coating area, at the mixers and at the screen area, employees were exposed to a caught in hazard, in that, portable and fixed conveyors did not have the in-going nip points guarded. c. Coating area, employees were exposed to a caught in hazard, in that, the front of the three Doyle rotating mixers were not guarded. d. Coating area, employees were exposed to a caught in hazard, in that, the barrier guards at the side of the three Doyle mixers were not of sufficient height to cover the rotating drums. e. Bagging area under the weight hopper, employees were exposed to a caught in hazard, in that, the in-going nip point on the conveyor was not guarded. f. Bagging area, at the hammer bagging conveyor system (a 3 section system), employees were exposed to a caught in hazard, in that, the in-going nip point was not guarded. g. Bagging area shrink-wrap machine, employees were exposed to a caught in hazard, in that, the shrink wrap machine was raised and then lowered while wrapping product. The pinch point created by the machine's shrink roll base was not guarded. h. Bagging area, at the mixer blend feed conveyor, employees were exposed to a caught in hazard, in that, the in-going nip point was not guarded. i. Bagging area, at the blend discharge conveyor, employees were exposed to a caught in hazard, in that, the in-going nip point was not guarded. j. Warehouse shrink-wrap machine, employees were exposed to a caught in hazard, in that, the shrink wrap machine was raised and then lowered while wrapping product. The pinch point created by the machine's shrink roll base was not guarded. k. Bagging area at the back of the Doyle mixer, employees were exposed to a caught in hazard, in that, the rotating drum on the back of the mixer was not guarded.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
1910.219 C04 I
- Issued
- Aug 22, 2014
- Abate by
- Nov 3, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded rotating shaft ends projected more than one-half the diameter of the shaft: a. Coating area, employees were exposed to a caught in hazard, in that, two portable conveyors had exposed shaft ends one inch in diameter protruding 2 and 3 inches without a guard. b. Bagging area, at the blend discharge conveyor, employees were exposed to a caught in hazard, in that, a shaft end 1.25 inches in diameter extended 2.25 inches without a guard.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.242 B
- Issued
- Aug 22, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. Material discharge area at preheater, employees were exposed to a struck by hazard when using compressed air for cleaning at 100 psi.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.253 E03 II C 2
- Issued
- Aug 22, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.253(e)(3)(ii)(C)(2): Backflow protection was not provided by an approved device that would prevent oxygen from flowing into the fuel gas system or fuel from flowing into the oxygen system: a. At the maintenance shop, employees were exposed to a fire hazard, in that, the oxygen and acetylene torch and hoses used during maintenance activities were not equipped with a backflow prevention valve.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.253 E03 II C 3
- Issued
- Aug 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system: a. At the maintenance shop, employees were exposed to a fire hazard, in that, the oxygen and acetylene torch and hoses used during maintenance activities were not equipped with a flashback arrestor.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G01 II
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a. Coating area at the weight scale, employees were exposed to an electrical hazard, in that, the scale was located directly in front of the main disconnect. b. Maintenance storage area east wall, employees were exposed to an electrical hazard, in that, the area in front of the breaker panel was used for storage.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.303 G02 I
- Issued
- Aug 22, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a. Manufacturing area, at the battery charging station, employees were exposed to an electrical hazard, in that, the three fuse box for the chargers was bent causing the box to remain open exposing employees to the 240 volt terminals.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
1910.305 B01 II
- Issued
- Aug 22, 2014
- Abate by
- Sep 26, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. Coating area main disconnect near weight scale, employees were exposed to an electrical hazard, in that, a knockout on the side of the disconnect was not provided with a cover. b. Maintenance shop electrical panel, employees were exposed to an electrical hazard, in that, two breaker openings were not provided with covers. c. Research and development area breaker panel, employees were exposed to an electrical hazard, in that, two breaker openings were not provided with covers. d. Manufacturing area at the battery charging station, employees were exposed to an electrical hazard, in that, a knockout on the side of the disconnect for the "B" battery pack was not provided with covers. e. Bagging line area near the shrink-wrap machine, employees were exposed to an electrical hazard, in that, two breaker openings were partly covered using duct tape. f. Blend discharge area, at the variable speed frequency drive cabinet, employees were exposed to an electrical hazard, in that, two knockouts on the side of the disconnect were not provided with covers.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.305 G01 IV A
- Issued
- Aug 22, 2014
- Abate by
- Sep 26, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. West wall breaker panel, employees were exposed to an electrical hazard, in that, an extension cord was wired into the panel and was used in place of fixed wiring to operate portable tools and fans. b. Coating area weight scales, near the main disconnect, employees were exposed to an electrical hazard, in that, extension cords (red and blue) were used in place of fixed wiring. c. Tote rack area, employees were exposed to an electrical hazard, in that, a red extension cord providing power to the heating blanket was used in place of fixed wiring. d. Bagging line, employees were exposed to an electrical hazard, in that, extension cords (red and yellow) providing power to the equipment were used in place of fixed wiring. e. Coating area, employees were exposed to an electrical hazard, in that, extension cords were used in place of fixed wiring to provide power to the portable conveyors.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.305 G02 II
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a. Coating area at the Mixers, employees were exposed to an electrical hazard, in that, a hand held portable light used to provide lighting inside the mixers had a cord spliced with electrical tape.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.157 D04
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(d)(4): Portable fire extinguishers for use on Class B fires were not distributed so that the travel distance from the Class B hazard area to any extinguisher was 50 feet or less: a. At the propane fuel storage area, employees were exposed to a fire hazard, in that, the nearest fire extinguisher was 80 feet from the storage area.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B02
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Bagging area work station table, employees were exposed to an electrical hazard, in that, a metal 4-way outlet box was used as a pendant and was not installed on a surface as designed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Florikan ESA, LLC
View Florikan ESA, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325314)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339605248.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.