OSHA Inspection: V & V CONSTRUCTION CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of V & V CONSTRUCTION CORP. in 27 GRANITE ST., BROOKLYN, NY 11207 (NAICS 238130). OSHA activity number 339605263.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V & V Construction Corp. — free Get an email when a new federal OSHA severe-injury report for V & V Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
27 GRANITE ST.
City
BROOKLYN
State
NY
ZIP
11207
Mailing
79-11 41ST AVE. APT A109, JACKSON HEIGHTS, NY 11372
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 20, 2014
Abate by
Jun 2, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.     a) 3rd floor:     Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. The saw and the connected extension cord were not provided with a ground fault circuit interrupter. On or about 02/25/14.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 4 exposed
Issued
May 20, 2014
Abate by
Jun 2, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.     a) 3rd floor:     Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. Both the saw's power cord and the connected extension cord were missing ground pins. On or about 02/25/14.        NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.405 B02

Serious Gravity 5 1 instance 4 exposed
Issued
May 20, 2014
Abate by
Jun 2, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.     a) 3rd floor:     Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. The temporary outlet was energized and the outlet box did not have a cover. On or about 02/25/14.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.501 B04 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 20, 2014
Abate by
Jun 2, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.     a) 3rd floor:     Employees were framing on the 3rd floor, which the entire floor was removed during ongoing demolition operations and was not fully decked to cover all floor holes and openings. Employees were exposed falling approximately 10 feet through holes to the 2nd floor. On or about 02/25/14.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

View V & V Construction Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339605263.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.