Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UPSTATE FRAMING, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of UPSTATE FRAMING, INC. in 115 WINTERTON ROAD, BLOOMINGBURG, NY 12721 (NAICS 238130). OSHA activity number 339609430.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Upstate Framing, INC. — free Get an email when a new federal OSHA severe-injury report for Upstate Framing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
115 WINTERTON ROAD
City
BLOOMINGBURG
State
NY
ZIP
12721
Mailing
144 ROUTE 59, SUFFERN, NY 10901
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
11
Ownership type
A

8 citations on file for this inspection.

1926.451 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2014
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1926.451(b)(2):  Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide:    (a) Front of Building# B-39 - on or about January 27, 2014 - an employee was performing framing installations, working from a field-fabricated scaffold system that was not adequately planked.  Elevation of the scaffold deck to the ground was approximately 6 feet, 8 inches.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2014
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    (a) Front of Building# B-39 - on or about January 27, 2014 - an employee was performing framing installations, working from a field-fabricated scaffold system that was not provided with an adequate means of egress.  Elevation of the scaffold deck to the ground was approximately 6 feet, 8 inches.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 24, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a) Building# B-38 - on or about January 27, 2014 - employees were performing wood framing installations on the second story floor deck.  No fall protection was available.  Ground to second story elevation was approximately 11 feet.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.20 B02

Serious Gravity 5 1 instance 8 exposed
Issued
Apr 24, 2014
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    (a) Jobsite - on or about January 27, 2014 - the employer did not provide frequent and regular inspections of the jobsite.  Observed hazards include fall hazards from floor decks and scaffolds, electrical hazards, puncture hazards, burn hazards and hazards from a lack of personal protective equipment.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.451(f)(7):  Scaffolds were not erected, moved, dismantled or altered by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration.  Such activities were not performed by experienced and trained employees selected for such work by the competent person:    (a) Front of Building# B-39 - on or about January 27, 2014 - an employee was performing framing installations, working from a field-fabricated scaffold system that was not erected by a scaffold competent person.  Elevation of the scaffold deck to the ground was approximately 6 feet, 8 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.152 A01

Other-than-serious 1 instance 1 exposed
Issued
Apr 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.152(a)(1):  Containers and portable tanks used for the storage and handling of flammable and combustible liquids were not approved:  (a) Front of Building# B-38 - on or about January 27, 2014 - the five gallon container of gasoline was not equipped with a proper cap.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Apr 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) Front of Building# B-38 - on or about January 27, 2014 - the extension cord that was supplying electric to the Makita 7-1/4" circular saw was not provided with a continual path to ground.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Apr 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:  (a) Front of Building# B-38 - on or about January 27, 2014 - the extension cord that was supplying electric to the Makita 7-1/4" circular had insulation damage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Upstate Framing, INC.'s full OSHA safety record →