Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THERMO PAC, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of THERMO PAC, LLC in 1609 STONE RIDGE DRIVE, STONE MOUNTAIN, GA 30083 (NAICS 311999). OSHA activity number 339612723.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thermo PAC, LLC — free Get an email when a new federal OSHA severe-injury report for Thermo PAC, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
THERMO PAC, LLC
Site address
1609 STONE RIDGE DRIVE
City
STONE MOUNTAIN
State
GA
ZIP
30083
Mailing
1609 STONE RIDGE DRIVE, STONE MOUNTAIN, GA 30083
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
152
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 29, 2014
Penalty
Initial $6,300 · Current $3,780 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to chemical incompatibility hazards.   On or about March 3, 2014:     Employees working in the lab area are exposed to flash fire hazards from the employer improperly storing incompatible chemicals together in the same storage cabinet. Flammables were not separated from the acids and the nitric acid was not stored in a separate containment or compartment from the other acids such as but not limited to acetic acid.
Recent events (2)
  • — I (S) $3780
  • — Z (S) $6300

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 29, 2014
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:      On or about March 3, 2014:    Employees working in the processing room on the peanut side of the production area were exposed to eye irritants.  The employer did not ensure that the eyewash station was working properly.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.303 B07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 29, 2014
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.    On or about March 3, 2014:  Employees working in the pack-out room on the peanut side of the production area were exposed to electrical hazards.  The employer did not ensure that the unused opening in the hanging electrical outlet box was effectively closed.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    On or about March 3, 2014:  Employees working in the pack-out room on the peanut side of the production area were exposed to electrical hazards.  The employer did not ensure that all hanging electrical outlet boxes had strain relief to prevent exposure to wires.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Thermo PAC, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339612723.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.