Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLINGAN STEEL INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CLINGAN STEEL INC. in 2525 ARTHUR AVE, ELK GROVE VILLAGE, IL 60007 (NAICS 331221). OSHA activity number 339612848.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clingan Steel INC. — free Get an email when a new federal OSHA severe-injury report for Clingan Steel INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CLINGAN STEEL INC.
Site address
2525 ARTHUR AVE
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
2525 ARTHUR AVE, ELK GROVE VILLAGE, IL 60007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
75
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 3 instances 6 exposed
Issued
Mar 31, 2014
Abate by
Jun 2, 2014
Penalty
Initial $4,410 · Current $3,000 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    (a) Production - The employer did not ensure that lockout tagout devices were applied to isolate energy sources on Slitter 1 when employees were performing maintenance tasks. Employees could have been injured by the energized equipment while performing setting up procedures.    (b) Production - The employer did not ensure that lockout tagout devices were applied to isolate energy sources on Slitter 2 when employees were performing maintenance tasks. Employees could have been injured by the energized equipment while performing setting up procedures.    (c) Production - The employer did not ensure that lockout tagout devices were applied to isolate energy sources on Slitter 3 when employees were performing maintenance tasks. Employees could have been injured by the energized equipment while performing setting up procedures.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4410

1910.212 A01

Serious Gravity 10 3 instances 8 exposed
Issued
Mar 31, 2014
Abate by
Jun 2, 2014
Penalty
Initial $4,410 · Current $3,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by in-going nip points and rotating parts;    (a) Facility Wide - The employer did not ensure that guards or methods of guarding were permanently affixed to the machine to protect employees from rotating parts on Edger 1.     (b) Facility Wide - The employer did not ensure that guards or methods of guarding were used to protect employees from rotating knives at the out-feed section on all slitters.    (c) Facility Wide - The employer did not ensure that guards or methods of guarding were used to protect employees from in going nip points on Slitter 3 at the in-feed section.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4410

View Clingan Steel INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339612848.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.